Download Print this page

Bowers & Wilkins PV1D User Manual page 10

Hide thumbs Also See for PV1D:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
5.2 Initial Setup
Setup
Display
Dim
On/Off
Auto
Trigger 2
Audio
About
About
Model
PV1D
Software
1.0.0
When the PV1D enters setup mode it will display the
setup Home Menu illustrated above left.
The five menu items provide the following functions:
Display
By default, the display is set to dim and the navigation
buttons fade completely after 30 seconds of button
inactivity to reduce visual distraction in normal
operation. Alternatively, the display may be set to go
off altogether. As soon as any button area is pressed,
the display and buttons become fully bright and always
remain bright when in setup mode.
On/Off
In this context, Off refers to the Standby condition.
To fully disconnect the PV1D from mains
power, it is necessary to switch off the
power outlet socket or withdraw the
power plug.
Select RS-232 if an RS-232-based home automation
system is to be used to switch between on and off, or
if you wish to disable the Auto function.
10
Audio
Trigger 2
Out
Inputs
Speaker
In
List
Presets
If Auto is selected, the PV1D will switch on
automatically when an input audio signal is detected
and off following a specified time after the input signal
stops.
The automatic switch-off delay time can be set in the
subsequent menu by pressing the
Auto is highlighted. Accessing the delay time will also
select Auto as the switching method.
If Trigger 1 is selected, 12V at the Trigger 1 input will
switch the PV1D on and 0V will switch it off.
The default on/off method is Auto and the default turn-
off time is 30 minutes.
To proceed with PV1D setup, ensure
that the On/Off parameter is initially
set to RS-232. Reset it if required
when all other parameters have
been configured.
Note: The logo On/Standby button on the PV1D may
always be used to switch between On and Standby,
regardless of the setting of the On/Off parameter on
the screen.
Trigger
Off
Preset 1
On
Preset 2
Trigger On (12V)
Preset 1
Preset 2
Preset 3
Preset 4
Preset 5
Trigger 2
Enables any two PV1D presets to be selected in turn
by a 12V control signal on the Trigger 2 input. Selecting
In engages this control feature and selecting Out
disengages it. Out should be selected if your PV1D is
button when
integrated within an RS232 home automation system.
The default is Out.
Pressing the
Trigger 2 as the switching mode and allows the user
to select which Presets correspond to 12V and 0V at
the Trigger 2 input. If In is the selected mode, Preset
switching via the front panel buttons in normal mode is
then disabled.
The default presets are Preset 1 for 0V and Preset 2
for 12V.
Audio
The Audio option in the setup home page provides
access to all the PV1D audio setup parameters.
Select Audio to move on to the next setup stage.
About
Displays the PV1D model number and internal software
(firmware) version.
Display
Dim
Off
On/Off
RS-232
Auto
30 min
Trigger 1
Trigger Off (0V)
Auto Off Delay
Preset 1
30 min
Preset 2
60 min
Preset 3
90 min
Preset 4
120 min
Preset 5
180 min
button while In is highlighted sets

Advertisement

loading