PERIODIC MAINTENACE
Twice a month, flush a white vinegar solution (one
quart vinegar to two gallons of water) or anti-
browning solution (mixed as directed) through the
machine. This will prevent build-up of alkaline
residue in the system. If spray jets become clogged,
remove the spray tips, wash them thoroughly, and
blow dry.
NOTE: Do not use pins, wires, etc. to clean nozzles
as this could destroy the spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked
hoses should be repaired or replaced to eliminate
vacuum or solution pressure loss. The electrical
cable must be well insulated and cable connector
screw kept tight. If the cable insulation is broken or
frayed, repair or replace immediately. Don't take
chances with elctrical fire or shock.

SERVICE SCHEDULE

Check machine for cord damage
Check recovery dome and gasket for damage and
cleanliness
Check hoses for wear, blockages, or damage
Check handles, switches, and knobs for damage
Check vac motor intake filter and clean
Run one gallon of water through system
Clean out recovery tank and check float valve to make
sure it moves freely
Clean out solution tank and remove and clean vacuum
intake screen
Clean outside of all tanks and check for damage
Run vac motor for at least one minute to allow motor to
dry
Store with dome off tank to allow the tank to dry
Check all bearings for noise
Check all gaskets for wear and leakage
Check vacuum intake screen for damage; replace if
necessary
Check pump pressure; observe spray pattern and
check with gauge if necessary
Check and clean solution screen
Check cables for fraying
Check overall performance of machine
Check vac motor carbon brushes
DAILY/REGULAR MAINTENANCE
Before making any adjustments to the machine,
disconnect the power cord from the electrical source.
1. Empty unused cleaning solution from the
solution tank.
2. Inspect and clean filter screen in solution tank.
3. Flush pumping system with 4 to 7 liters of clean
water.
4. After each use, rinse tank with fresh water.
Periodically inspect the recovery tank and
decontaminate if necessary, using a Hospital
Grade Virucide or a 10-1 bleach to water
solution. Waste water should be disposed of
properly.
5. Remove filter to clean. Filters used for wet pick-
up including striper must be thoroughly cleaned
before being allowed to dry.
6. Check spray jets for full spray pattern.
86343680 AP 100/50 M
MAINTENANCE
DAILY
WEEKLY
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
QUARTERLY
*
4-5