Vacuum Motor Replacement - Kärcher AP 100/50 M Operating Instructions Manual

Multi-functional cleaning
Hide thumbs Also See for AP 100/50 M:
Table of Contents

Advertisement

4. VACUUM MOTOR
(Refer to vacuum group in the parts section of
manual).
ONLY QUALIFIED MAINTENANCE PERSONNEL
ARE TO PERFORM THE FOLLOWING REPAIRS.

VACUUM MOTOR REPLACEMENT

1. Turn off all switches and unplug machine.
2. Remove recovery tank.
3. Remove the 5 screws holding the vacuum motor
cover to the solution tank.
4. Locate the vacuum motor wires and disconnect
at the connector.
5. Remove the vacuum motor.
6. Reverse process to install.
Vacuum Motor Carbon Brushes Replacement
Carbon
Brushes
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a
qualified service center.
Important:
These brushes wear quicker as the length shortens due to
increased heat. Spring inside brush housing will damage
motor if brushes are allowed to wear away completely.
Periodically check the length of the carbon brushes. Replace
both carbon brushes when either is less than 3/8" (9.5mm)
long.
86343680 AP 100/50 M
MAINTENANCE
End Cap
WARNING: The green
ground wire must be
attached for safe operation.
See wiring diagram.
3
8 [9.5mm]
4-3