Control Box Board (5), Code 5.602.033 (On Module Hv18); Hf Board (2), Code 5.602.034 (On Module Hv18) - Cebora PLASMA PROF 164 HQC Service Manual

Hide thumbs Also See for PLASMA PROF 164 HQC:
Table of Contents

Advertisement

CEBORA S.p.A.
5.12

- Control box board (5), code 5.602.033 (on module HV18).

5.12.1 - Topographical drawing.
5.12.2 - Connector tables.
Conn. Terminals
J1
A - B
J2
A - B
J3
-
J4
-
J5
1 - 2
J5
3 - 4
TP1
TP2
TP3
5.13

- HF board (2), code 5.602.034 (on module HV18).

5.13.1 - Topographical drawing.
5.13.2 - Connector table.
Conn. Terminals
-
CN1 - CN4
-
CN2
-
CN3
3.302.218
Function
NU. (start input from torch button).
"guard open" signal output, on module HV18.
Power Source output voltage input, nozzle potential.
output voltage output for torch, nozzle potential.
NU.
"guard open" signal input, on module HV18.
output voltage output, nozzle potential, for HF board (2).
output voltage output, electrode potential, for HF board (2).
output voltage input, from Power Source, electrode potential.
Function
output for HF transformer (7) primary circuit, on module HV18.
output voltage input, nozzle potential, from control box board (5).
output voltage input, electrode potential, from control box board (5).
53
9/8/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents