Remote Board (59), Code 5.602.252 - Cebora PLASMA PROF 164 HQC Service Manual

Hide thumbs Also See for PLASMA PROF 164 HQC:
Table of Contents

Advertisement

CEBORA S.p.A.
5.11

- Remote board (59), code 5.602.252.

5.11.1 - Topographical drawing.
5.11.2 - Connector table.
Conn. Terminals
J1
-
J2
1 - 9
J2
2 - 10
J2
3 - 11
J2
4 - 12
J2
5(+) - 13(-)
J2
6(+) - 8(-)
J2
16(+) - 8(-)
J3
1 - 2
J3
3(+) - 4(-)
J3
5(+) - 6(-)
J3
7(+) - 8(-)
J3
9(+) - 10(-)
J4
1(+) - 2(-)
J5
1 - 2
J6
1(+) - 2(-)
3.302.218
Function
GND.
"start" signal input.
"emergency stop" signal input, from system.
"operating permission" (interlock) signal input, from system.
"transfer arc" signal output.
external analog current reference input.
"isolated arc voltage" signal output.
"not isolated arc voltage" signal output.
"transfer arc" signal input.
external digital current reference output.
"operating permission" (interlock) signal output, from system.
"emergency stop" signal output, from system.
"start" signal output.
"arc voltage" signal input, for remote board (59).
230 Vac input, for remote board (59) power supply.
"auxiliary arc voltage" digital signal input.
52