en | Maintenance
8

Maintenance

No special maintenance is required other than occasionally cleaning the window with water or
any non-aggressive liquid.
8.1

Fuse replacement

1.
2.
3.
Housing voltage
24 VAC
120 VAC
230 VAC
There is a spare fuse inside the housing.
2014.11 | 1.0 | F.01U.309.609
To replace a fuse, push and twist the fuse holder to open it.
Replace the fuse with a fuse that has the same current rating. The fuse is a 5 mm x
20 mm slow blow breaking capacity cartridge-type fuse.
Push and twist the fuse holder to close it.
Fuse rating
4 A, 250 VAC
2 A, 250 VAC
2 A, 250 VAC