Program Upload

Reset

Resetting
Calibration
Defaults

Setting the

White Color

COLORado™ 1-Quad IP User Manual Rev. 5
This option allows you to copy the custom programs of one COLORado™ 1-Quad IP onto
other COLORado™ 1-Quad IP's by using the Master/Slave mode.
1. Configure and connect the products in a Master/Slave arrangement, where the master
has the custom programs you want to transfer to the slaves.
2. From the master, go to the SET main level.
3. Select UPLD.
4. When PASS shows, press <ENTER>.
5. Enter the passcode as shown in Passcode.
6. When SEND shows, press <ENTER> to start the upload.
7. Wait for the upload process to finish (the display will show END before continuing or
turning the products off).
The Master/Slave products will provide the status of the process by lighting up as follows:
·
Yellow indicates that the upload process is running.
·
Green indicates that the upload process completed successfully.
·
Red indicates that the upload process failed due to an error. Recheck all cable
connections and restart the process. If the issue persists, contact Chauvet Technical
Support.
DO NOT upload the data from a COLORado™ 1-Quad IP to a different product. The
other product may become inoperative.
This setting allows you to reset the COLORado™ 1-Quad IP to the default values,
including the custom programs.
1. Go to the SET main level.
2. Select REST.
3. When PASS shows, press <ENTER>.
4. Enter the passcode as described in Passcode.
5. Wait for the reset process to finish.
This setting allows you to reset the product's default values set in the CAL1 and CAL2
programming levels. (See
White Color
for CAL2 settings.)
1. Go to the CAL main level.
2. When PASS shows, press <ENTER>.
3. Enter the passcode as described in Passcode.
4. Select CALR.
5. Enter the passcode as described in Passcode.
6. Wait for the reset process to finish.
This setting allows you to select and edit the color temperature of the white (macros) when
in the TOUR, TR16, or FULL modes.
1. Go to the CAL main level.
2. Enter the passcode as described in Passcode.
3. Go to CAL1.
4. Select a white color (WH.01–11).
5. Select a color (RED, GREN, BLUE, or WHIT).
6. Select a color value (000–255).
7. Repeat for the other colors.
Setting the White Color