Control Panel Lock; Program Upload; Reset; Whites Setting - Chauvet COLORado 2 Tour User Manual

Hide thumbs Also See for COLORado 2 Tour:
Table of Contents

Advertisement

Operation

Control Panel Lock

Program Upload

Reset

Whites Setting

-12-
Continued from previous page
This setting allows the user to activate or disable the control panel lock, which keeps
non-authorized personnel from changing the fixture's settings.
1) Press <MENU> repeatedly until KEY shows; press <ENTER> to accept.
2) Use <UP> or <DOWN> to select On or Off; press <ENTER> to accept.
When the control panel lock is active, the fixture will prompt the user to enter the
password after 30 seconds of control panel inactivity or after turning on the
fixture.
After being prompted to enter the fixture password:
1) Press <UP>, <DOWN>, <UP>, <DOWN>, and <ENTER>
The above fixture password is unchangeable.
This option allows the user to copy the custom programs of one COLORado™ 2 Tour
fixture onto other COLORado™ 2 Tour fixtures by using the Master/Slave method.
1) Configure and connect the fixtures in a Master/Slave arrangement, where the
master unit has the custom programs you want to transfer onto the slave units.
2) At the master unit, press <MENU> repeatedly until SET shows; press <ENTER> to
accept.
3) Use <UP> or <DOWN> to select UPLD; press <ENTER> to accept.
4) When prompted, enter the master access password as shown in Control Panel
Lock.
5) Wait for the upload process to finish before disconnecting the fixtures.
During and after the upload, the master and slave units will visually indicate the
status of the process, as follows:
Yellow means that the upload is running.
Red means that the upload failed due to an error.
Green means that the upload completed successfully.
This setting allows the user to reset the COLORado™ 2 Tour fixture to its default
values, including the custom programs.
1) Press <MENU> repeatedly until SET shows; press <ENTER> to accept.
2) Use <UP> or <DOWN> to select REST; press <ENTER> to accept.
3) When prompted, enter the master access password as shown in Control Panel
Lock.
4) Wait for the reset process to finish.
This setting allows the user to select and edit the temperature of the white colors used
in the Macro DMX channel.
1) Press <MENU> repeatedly until CAL1 shows; press <ENTER> to accept.
2) Use <UP> or <DOWN> to select a white color (WT. 1~11).
3) Press <ENTER> to accept.
This selects the white color as it is. To edit it, do as follows:
4) Use <UP> or <DOWN> to select a color (Red, Green, Blue, or White).
5) Press <ENTER> to accept.
6) Use <UP> or <DOWN> to select a color value (0~255).
7) Repeat for the other colors.
8) Press <MENU> to exit once done.
Continues on the next page
COLORado™ 2 Tour User Manual Rev. 02b

Advertisement

Table of Contents
loading

Table of Contents