Color Adjustment; Dimmer Curves; Control Panel Lock; Program Upload - Chauvet COLORado 1 tour User Manual

Colorado 1 tour
Hide thumbs Also See for COLORado 1 tour:
Table of Contents

Advertisement

Color Adjustment

Dimmer Curves

Control Panel Lock

Program Upload

COLORado™ 1 Tour User Manual Rev. 01h
Continued from the previous page
The COLOR setting determines how the COLORado™ 1 Tour displays the white color
when the Red, Green and Blue faders are all at the "255" value.
1) Go to SET > Color.
2) Select OFF, RGBW, or UC.
Setting
Description
OFF
When R, G, and B are "255," the output will be at its maximum.
RGBW
When R, G, and B are "255," CAL2 will determine the output.
When R, G, and B are "255," the output will match that of fixtures
UC
from previous generations.
This setting determines how the output of the COLORado™ 1 Tour follows the position
of the Dimmer fader as well as the Red, Green, Blue, and White faders.
1) Go to SET > Dim.
2) Select a dimmer curve (Off, Dim1, Dim2, Dim3, or Dim4).
Setting
Description
OFF
The output is proportional to the faders' position (linear)
Dim1
The output is not proportional (fastest)
Dim2
The output is not proportional (fast)
Dim3
The output is not proportional (slow)
Dim4
The output is not proportional (slowest)
This setting allows the user to activate or disable the control panel lock, which keeps
non-authorized personnel from changing the fixture's settings.
1) Go to KEY.
2) Select On/ Off.
When the control panel lock is active, the fixture will prompt the user to enter the
password after 30 seconds of control panel inactivity or after turning on the
fixture.
After being prompted to enter the password:
1) Press <UP>, <DOWN>, <UP>, <DOWN>, and <ENTER>.
This option allows the user to copy the custom programs of one COLORado™ 1 Tour
fixture onto other COLORado™ 1 Tour fixtures by using the Master/Slave method.
1) Configure and connect the fixtures in a Master/Slave arrangement, where the
master unit has the custom programs you want to transfer onto the slave units.
2) At the master unit, go to SET > UPLD.
3) When prompted, enter the master access password as shown in Control Panel
Lock.
4) Wait for the upload process to finish before disconnecting the fixtures.
During and after the upload, the master and slave units will visually indicate the status
of the process, as follows:
Color
Meaning
Yellow
The upload process is running
Red
The upload failed due to an error
Green
The upload finished successfully
Continues on the next page
Operation
-11-

Advertisement

Table of Contents
loading

Table of Contents