Split system alarm with two point engine immobilisation for ed, ef & el falcon, vps2, vr/vs &vt commodore, & te magna (6 pages)
Summary of Contents for RHINO Rhino RAv3
Page 1
“RES2001”? For details, please refer to page 12 Instruction Manual Thank you for purchasing a Rhino Alarm and Engine Immobilisation system. Please read this manual carefully before commencing installation and keep it in a safe place for future reference.
Contents Contents ................................. 2 System Features ..............................3 Standard System Features ..........................................3 Selectable System Features ..........................................3 Optional Accessories ............................................3 Detailed Feature Descriptions ........................... 4 Automatic Immobilisation ........................................... 4 Automatic re-arm & relock (Programmable) ................................... 4 Door Ajar Warning (Programmable) ......................................4 Timed Headlight Delay (Optional connection by installer at extra cost) ........................
System Features Standard System Features • Microprocessor Controlled • Three Point Engine Immobilisation (Onboard Relays) • Auto Immobilise (Passive Arming) • Code Hopping Remote Technology (Anti-Scanning, Anti-Code Grabbing) • Two SSR™ Solid State Remote Controls with 4 Function Operation (Arm / Disarm, Boot Release, Panic) •...
Detailed Feature Descriptions Automatic Immobilisation The immobiliser will automatically activate 38 seconds after the ignition is switched off - This is indicated via the dash mounted LED, which will illuminate to confirm the system has entered auto immobilise mode. During this time the vehicle cannot be started until a valid remote has disarmed the system.
Furthermore the system features the unique Rhino "Auto Adjust” process, where during the 45 sec. arming delay, the alarm samples the background noise where the vehicle is parked, and will if necessary automatically reduce the sensitivity of the impact sensor to an appropriate level.
Alarm Operation Remote Control Functions: Remote Control Symbols Action on Alarm Arm/Disarm the Alarm System ⁄ Hold for Boot Release Alarm Panic Mode Optional Optional 4 Channel for Home Alarm...
Arming and Disarming Your Immobilizer TO ARM YOUR IMMOBILISER (& lock your vehicle if central locking is connected) Pressing the ⁄ button on the remote control transmitter activates the immobiliser. The blinkers will flash once ⁄ and the siren will beep once. For silent arm / disarm press both buttons If central locking is connected, your doors will lock.
How to Program the Selectable Features Your Rhino Security system incorporates the latest in high security & convenience features. It is possible to customise your security system so that it suits your requirements perfectly. Detailed below is the full list of programmable features that can either be turned on or turned off.
How to Change REGISTER 1: Vehicle Set Up: CLOSED AND T OORS GNITION URNED Remote Key action: T EATURES UTTON EMOTE Press FACTORY FEATURE Remote DESCRIPTION SETTING This Many Times Arming & Disarming Beeps 1 beep on Arm & 2 beeps on Disarm. Door Lock on Ignition When this feature is on, the doors will lock when the ignition is turned to on, and unlock when the ignition is turned to off.
Page 10
After pressing the remote 13 times to enter this mode, turn the Memory to replay ignition off. Your Rhino Alarm offers a unique memory that memory stores the ten last reasons why the alarm was triggered. This memory cannot be erased.
Remote This Many Times LEFT Button Used To This is activated if you have two cars with Rhino remote controls, Arm/Disarm This Vehicle the vehicle that this is feature is activated on will use the left button to arm disarm and loose the ability to activate the boot release output.
Important! This connector is electrically compatible ONLY with the RAv3 and previous RAv2 and JAG alarm system - Even though the RAv3 plug looks the same as connectors used in earlier Rhino RES4601 and RA models, THEY ARE NOT COMPATIBLE.
Factory Remote Interface Connection POS1 POS2 NEG1 NEG2 Modes of Operation: Inhibit mode (Register 1 Feature 10): In inhibit mode the alarm will be armed and disarmed by M1/M2 and POS1/POS2. If a negative signal is detected by NEG1 or NEG2 arming or disarming will be inhibited.
Page 14
Enable mode (Register 1, Feature 10): In enable mode the POS1 wire must see a positive signal to enable the system to arm or disarm. This is often hooked up to the indicators if they flash on arming or disarming. Wire Enable mode POS1...
Siren Connect this wire to the siren output wire from your siren. Note: You can only connect to specially coded Rhino sirens (BBSC). This output is not compatible with any other brand of siren as coded data is transmitted to turn the siren on and off.
Installing the Coded Battery Backup Siren (BBSC / MiniBBSC): +12V: Connect to constant 12V power BLACK GND: Connect to vehicle ground WHITE SIREN: Connect to wire 16 on main unit GREEN -ALARM: Negative on alarm output BROWN BONNET: Connect to wire 20 on main unit BONNET: Connect to bonnet switch Red - 12V Siren Power: Connect to permanent 12v power source –...
Installing Timed Headlight Delay Note: A 40 Amp Changeover Relay is required. Connecting to an Existing Electric Boot (Trunk) Release Motor Note: A 40 Amp Changeover Relay is required. +12VDC (Fused 15A) “BOOT -OUT” wire from Module Boot Motor...
Page 19
Vehicles fitted with an interior light delay require a diode to be added to prevent the system giving a door ajar warning. Please follow the wiring diagram below: +12V Interior light DOOR DELAY CIRCUIT Door wire White wire Place a diode here RHINO Door Switches...
Central Door Lock Diagrams 1. Negative pulse CDL system: Unlock NC Unlock COM Connect to unlock wire of vehicle Unlock NO Earth Lock NC Lock COM Connect to lock wire of vehicle Lock NO Earth 2. Positive pulse CDL system: Unlock NC Connect to unlock wire of vehicle Unlock COM...
Page 21
5. Single wire CDL system: Unlock NC Unlock COM Connect to relay side of control wire Unlock NO Earth Connect to door side of control wire Lock NC Lock COM Connect to Unlock COM Lock NO 6. Flow thru CDL system: Unlock NC Unlock COM Unlock NO...
WARRANTY TERMS & CONDITIONS RhinoCo Technology (The Company) warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 12 months from the date stamp control on the product, or for products not having a date stamp, for twelve months from the date of original purchase unless the installation instructions or catalogue sets forth a shorter period, in which case the shorter period shall apply.
Need help?
Do you have a question about the Rhino RAv3 and is the answer not in the manual?
Questions and answers