2 Flashes
= High Temperatureof the Inverter System. The
unit has been overloadedto the point where the
internaltemperatureof the inverter hasexceeded
212°E
3 Flashes--Overload. The unit has been overloaded to
the point that the output power required has
exceeded110% of ratedpower.
4 Flashes= Short Circuit. This indicatesthe unit's output has
been short circuited by the load connectedto it.
Figure 2 - Unit Identification
1
2
20. 120 VAC Receptacles:Two (2) receptacles for connecting
devices.
NOTE:
Do not exceedthe rated outputof the generator.
Figure3 - ControlPanel
13_
14--
15--
16--
17--
Fo
@
o
18
19
20
7\
11
10
9
3
8
16. 12 VDC Plug: Connectionfor re-charging 12VDCautomotive-
style batterieswhile generatoris in operation.
17. FlexPower
T M
Switch: This switch slows the engine speed
when the load is reducedto save fuel and engine wear.
18. 12 VDC Circuit Breaker:Overload protectionfor the 12 VDC
charging system.
19. Ground (Earth) Connection Lug: Grounding point for the
generator; consult state and local electrical codes before use
(floating ground).
PRE-USE CHECK
Prior to starting the generator and adding loads, perform the
following tasks:
1. Make sure the generatorin on a firm, level, non-combustible
surface with at leastfive (5) feet of clearanceon all sides.
Never operate
in an enclosed
area or
indoors! NEVER use in the home, in a
vehicle, or in partly enclosed
areas such
as garages,
even if doors and windows
are
open! ONLY use outdoors and far from open
windows,
doors, vents, and in an area that
will net accumulate
deadly
exhaust.
The engine exhaust fumes
contain carbon
monoxide,
which you cannot see or smell.
This poisonous
gas, if breathed
in sufficient
concentrations,
can cause unconsciousness
or even death.
Adequate,
unobstructed
flow of cooling and
ventilating
air is critical to correct generator
operation.
Do net alter the installation
or
permit even partial blockage of ventilation
provisions,
as this can seriously
affect safe
operation
of the generator. The generator
MUST be operated
outdoors.

Hide quick links: