Temperature-Related System Shutdown; Hard Disk Drive Checkout - IBM IntelliStation Z Pro 6223 Hardware Maintenance Manual And Troubleshooting Manual

Hide thumbs Also See for IntelliStation Z Pro 6223:
Table of Contents

Advertisement

Note: See "System replaceable units" on page 117 to determine which components should be replaced by a field
service technician.
Message
System shutoff due to x V under voltage
(level-critical; system shutoff due to x
supply under voltage)
System shutoff due to VRM x over
voltage
System shutoff due to excessive (< 240
VA) loading

Temperature-related system shutdown

Note: See "System replaceable units" on page 117 to determine which components should be replaced by a field
service technician.
Message
System shutoff due to board over
temperature
(level-critical; board is over temperature)
System shutoff due to CPU x over
temperature (level-critical; CPU x is over
temperature)
System shutoff due to CPU x under
temperature (level-critical; CPU x is under
temperature)
System shutoff due to DASD temperature
(sensor x) (level-critical; DASD area
reported temperature outside recommended
operating range)
System shutoff due to high ambient
temperature
(level-critical; high ambient temperature)
System shutoff due to system board
under temperature
(level-critical; system board is under
temperature)

Hard disk drive checkout

Note: See "System replaceable units" on page 117 to determine which components should be replaced by a field
service technician.
Message
Hard drive x removal detected
(level-critical; hard drive x has been
removed)
Action
1. Check the power-supply connectors.
2. Power supply.
3. Power cage assembly, if installed.
v Replace VRM x.
1. See "Power checkout" on page 22.
2. Cycle ac on/off.
Action
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 23.
2. Replace board.
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 23.
2. Replace microprocessor x.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
v Ensure that the system is being properly cooled; see "System
reliability considerations" on page 23.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
Action
v Information only; take action as appropriate.