Outback Power Systems FXR2012E Operator's Manual page 81

Fxr series inverter/charger
Table of Contents

Advertisement

Field
Aux Control
Aux Mode
(Load Shed) ON: Batt >
(Load Shed ON) Delay
(Load Shed) OFF: Batt <
(Load Shed OFF) Delay
(Gen Alert) ON: Batt <
(Gen Alert ON) Delay
(Gen Alert) OFF: Batt >
(Gen Alert OFF) Delay
Auxiliary Output
(Vent Fan) ON: Batt >
(Vent Fan) Off Delay
(DC Divert) ON: Batt >
(DC Divert ON) Delay
(DC Divert) OFF: Batt <
(DC Divert OFF) Delay
(AC Divert) ON: Batt >
(AC Divert ON) Delay
(AC Divert) OFF: Batt <
(AC Divert OFF) Delay
Inverter Stacking
Stack Mode
Mode = Master:
Power Save
Ranking
Mode = Slave:
Offset Enable
Grid-Tie Sell
Sell Voltage
AC Input Voltage
Calibrate
AC Output Voltage
Battery Voltage
Grid Interface Protection Menu
Operating Frequency
Operating Frequency
Stage 1 Voltage Trip
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Stage 2 Voltage Trip
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Frequency Trip
Over Frequency Clearance Time
Over
Frequency Trip
Under Frequency Clearance Time
Under
Frequency Trip
Clearance Time
Mains Loss
Reconnect Delay
Multi-Phase Coordination
Maximum Sell
Sell Current Limit
Current
Model Select
900-0169-01-00 Rev A
Table 24
FXR Settings for 48-Volt Models
Item
Master Power Save Level
Slave Power Save Level
60-Hz system
50-Hz system
60-Hz system
50-Hz system
Coordin. AC Connect/Disconn.
FXR2348E
VFXR3048E
Default
Minimum
Auto
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
Vent Fan
DC Divert, GT Limits, Source Status, AC Divert
56.0 Vdc
0.5 minutes
0.1 minutes
44.0 Vdc
0.5 minutes
0.1 minutes
44.0 Vdc
0.5 minutes
0.1 minutes
56.0 Vdc
0.5 minutes
0.1 minutes
56.0 Vdc
0.5 minutes
0.1 minutes
56.0 Vdc
0.5 minutes
0.1 minutes
44.0 Vdc
0.5 minutes
0.1 minutes
56.0 Vdc
0.5 minutes
0.1 minutes
44.0 Vdc
0.5 minutes
0.1 minutes
Master
Master, Slave, B Phase Master, C Phase Master
0
1
Y
52.0 Vdc
X
0 Vac
X
0 Vac
X
0.0 Vdc
50 Hz
X
X
1.5 seconds
0.12 seconds
X
252 Vac
X
1.5 seconds
0.12 seconds
X
208 Vac
X
0.2 seconds
0.12 seconds
X
264 vac
0.2 seconds
0.12 seconds
X
X
196 Vac
X
0.16 seconds
0.12 seconds
61.0Hz
X
51.0 Hz
X
0.2 seconds
0.12 seconds
57.0 Hz
X
47.0 Hz
2.0 seconds
1.0 seconds
X
60 seconds
2 seconds
X
N
12 Aac
X
12 Aac
X
Vented
Specifications
Maximum
Off, Auto or On
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
40.0 Vdc
72.0 Vdc
25.0 minutes
0
10
1
10
Y or N
44.0 Vdc
64.0 Vdc
–7 Vac
7 Vac
–7 Vac
7 Vac
–0.8 Vdc
0.8 Vdc
50 Hz, 60 Hz
4.0 seconds
240 Vac
300 Vac
4.0 seconds
160 Vac
240 Vac
4.0 seconds
240 Vac
300 Vac
4.0 seconds
160 Vac
240 vac
5.0 seconds
60.2 Hz
65.0 Hz
50.2 Hz
55.0 Hz
5.0 seconds
55.0 Hz
59.8 Hz
45.0 Hz
49.8 Hz
25.0 seconds
302 seconds
Y or N
2.5 Aac
12 Aac
2.5 Aac
15 Aac
Vented or Sealed
81