Table 2 Summary Of Input Modes - Outback Power Systems FXR2012E Operator's Manual

Fxr series inverter/charger
Table of Contents

Advertisement

Mode
Summary
Generator Accepts power
from an
irregular or
low-quality
AC source
Adds battery
Support
power to
augment an
AC source that
has limited
output
Grid-
Inverter sells
excess power
Tied
(renewable)
to utility;
available in
24-volt and
48-volt
models only
In grid failure,
UPS
unit switches
to batteries
with fastest
possible
response time
Backup 
In grid failure,
unit switches
batteries to
support loads;
this is the
default mode
Mini Grid   Stays off grid
most of the
time; only uses
grid when
batteries low
GridZero 
On-grid but
actual grid use
is minimized
("zeroed") with
battery and
renewable
power; does
not sell or
charge
900-0169-01-00 Rev A
Table 2
Summary of Input Modes
Benefits
Can use AC that may be
unusable in other modes
Can charge even with a
poor generator or
low-quality AC source
Can use battery power
in conjunction with
AC source
Offset operation sends
excess DC to loads
Bidirectional input
Can reduce utility bills
and still provide backup
Offset operation sends
excess DC to loads
Any additional Offset
excess is sold to the grid
Quick backup for
sensitive devices during
grid outage
Simple use compared to
other modes; often
used with generators for
this reason
Less idle power than UPS
Does not drain battery as
in Support
Can minimize/eliminate
dependence on grid
Offset operation sends
excess DC to loads (but
only when on grid)
Can minimize
dependence on grid
Offset operation sends
excess DC to loads at
adjustable rate
Remains on-grid to avoid
transfer problems
Cautions
Will pass irregular or
low-quality power to
the output; could
damage sensitive loads
Offset unavailable
Drains batteries during
support; intended for
intermittent use only
May not function with
low-quality AC source
Requires utility
approval
Other approvals may be
required depending on
electrical codes
Has exact requirements
for accepting AC input
Requires renewable
energy source
Uses higher idle power
than other modes
Search function
unavailable
Offset unavailable
Has none of the special
functions described in
other modes
Will not work properly
unless renewable
source is above a
certain size
Conflicts with related
modes in MATE3
Discharges batteries
while remaining on grid
Will not work properly
unless renewable
source is above a
certain size
Battery charger
inoperative
Operation
Intended
Charger
Performs three-stage
Source:
charge and goes
Generator
silent as specified by
Loads:
settings
Non-
sensitive
devices
Source:
Performs three-stage
charge and goes
Grid or
silent as specified by
Generator
user settings
Loads:
Can be
larger than
AC source
Performs three-stage
Source:
Grid
charge and goes
silent as specified by
Loads:
user settings
Any type
Performs three-stage
Source:
charge and goes
Grid
silent as specified by
Loads:
user settings
PC, audio,
video, etc.
Performs three-stage
Source:
charge and goes
Grid or
Generator
silent as specified by
user settings
Loads:
Any type
Performs three-stage
Source:
Grid
charge on reconnect;
if charger is disabled,
Loads:
inverter emulates
Any type
charge cycle from
external source and
reacts accordingly
Charger inoperative;
Source:
batteries must be
Grid
charged using an
Loads:
external (renewable)
Any type
energy source
25

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FXR2012E and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vfxr2612eVfxr3024eVfxr3048Fxr2024eFxr2348e

Table of Contents