8.
Install the new tip cleaning brush, but do not tighten the mounting screws.
9.
With a glove on your hand, move the head so that the tips are above the tip cleaning brush.
10.
Adjust the tip cleaning assembly until the brush lightly touches the bottom of the Model Tip
Shroud.
Note:
Ideally, the top of the brush and the top of the flicker should be the same
height. Brush height, however is more important to tip maintenance than the
flicker height.
1 1.
Tighten the brush mounting screws.
Figure 27:
Replacing the tip cleaning brush
Top of brush just
touches bottom of Tip
Shroud
Flicker Screws
Brush mounting screws
Brush
40
Bottom of nipple must
hit brush and top half
of exposed flicker.
Flicker