Type of
heating element
(see
6.4.1)
Previous version
New version
If the system is in order, the
ohmmeter should indicate, in
measuring range "Ω x 1", a value of
about 2.5 Ω on previous heating
elements or between 7.2 Ω and
9.4 Ω on new heating elements
(see also 6.4.). If no reading is
obtained, there is a break in the
circuit. If the ohmmeter shows a
value of less than 2.5 Ω or 7.2 Ω,
there is a short circuit in one of the
components.
In either case it is necessary to
check each component separately.
The generator wire remains
disconneted from the heating
element during this check.
48
Reading in
Condition
Ω
approx. 2.5
OK
No reading
Break in
circuit
less than 2.5 Short circuit in a
component
7.2 - 9.4
in Ordnung
No reading
Break in
circuit
less than 7.2 Short circuit in a
component
Remedy
Check individual components -
10.1.2
Check individual components -
10.1.2
Check individual components -
10.1.2
Check individual components -
10.1.2
see
see
see
see
034, 036, 036 QS