 Remove the E-clip from the pivot
pin.
– Pull the hand guard and lever
from the pivot pins.
– Pull the lever out of the hand
guard.
 Remove the E-clip (3) from pivot
pin of lever (2) and detach the
spring (1).
 Remove the cam lever and
spring.
– Clean all disassembled parts in
white spirit. Replace any worn or
damaged parts.
034, 036, 036 QS
4.4.2

Installing

2
 Fit the cam lever (2) and
spring (1).
– Fit the E-clip.
1
2
3
 Insert lever in the side of the hand
guard so that short arm of lever
points up.
Note:
Check correct installed position of
lever.
 Position the hand guard (1)
against the pivot pin and fit the
other side of the hand guard over
the fan housing.
1
 Press the cam lever slightly
downward and push the hand
guard and lever onto the pivot
pins.
– Secure lever with E-clip.
– Insert hand guard mounting
screw with captive washer at fan
side and tighten down firmly (see
"Tightening Torques")
Important:
Coat all sliding and bearing points
with STIHL multipurpose grease,
see
13.2, or (better) with
molybdenum grease (e.g.
Molykote),
see
13.2.
Do not lubricate the brake band.
1
1
 First attach the brake band (1) to
the lever (2) and then push it into
the crankcase recess (arrow).