Glass specifications: Robax 5mm with dimensions of 17 3/32" x 9 13/16"
OVERLAY
4.3

GASKETING

It is recommended that you change the door gasket (which makes your stove door air tight) once a
year, in order to insure good control over the combustion, maximum efficiency and security. To
change the door gasket, simply remove the damaged one. Carefully clean the gasket groove, apply a
high temperature silicone sold for this purpose, and install the new gasket. Use only the genuine
Enerzone gasket. You may light up your stove again approximately 24 hours after having completed
this operation.
4.4

ASH REMOVAL USING THE ASH DRAWER

C
:
AUTION
ASHES CAN START FIRES
IN A COMBUSTIBLE CONTAINER
Whenever the ashes get 3 – 4" (76 – 102 mm) deep in the firebox, they should be emptied into the
ash drawer, using the following instructions:
 Make sure the fire is out, and the stove is cold.
 Lift the ash dump plug in the center of the firebox by hooking the poker through the loop
on the cover and lifting up.
GLASS RETAINER
DOOR FRAME
DOOR
,
EVEN AFTER SEVERAL DAYS OF INACTIVITY
. R
EMOVE ASHES WHEN THE STOVE AND ASHES ARE COLD
GLASS
FRAME
GLASS
. N
EVER DISPOSE OF ASHES
.
34