KHLDV Series Gas Fireplace
will automatically adjust the fl ame height according to the
difference between the Set temperature and the Room
temperature. There is no manual fl ame height adjustment.
The fan speed will also automatically adjust if turned on.
NOTE: When entering the Smart Mode
tion there will be a 10 second delay for the fl ame and
blower adjustment. When Smart Mode
erates automatically there can be up to a 3 minute delay
for fl ame/blower adjustment. Smart Mode
checks temperatures every 3 minutes. Also see AUX
Control.
1. When Set Temp. is 3° F or higher than Room Temp.,
fl ame height will be on High.
2. When Set Temp. is 2° F higher than Room Temp.,
fl ame height will be on Medium.
3. When Set Temp. is 1° F higher than Room Temp.,
fl ame height will be on Low.
4. When Set Temp. is equal to Room Temp., fl ame height
does not change (stays on low).
5. When Set Temp. is lower than Room Temp., the fi re-
place will be shut off.
6. When Set Temp. is 1° F higher than Room Temp.,
again the fl ame height will be on Low.
7. the fan speed follows the fl ame height, if the fan is
turned on.
®
To exit Smart Mode
thermostat and shut off the fi replace;
a. push and hold the THERMO buttons for 3 sec-
onds, Or
b. press the OFF button, Or
c. slide down on the arrow buttons.
To shut off the Smart Mode
to regular thermostat mode, press and hold the THERMO
button and the ON/UP button at the same time for 3 sec-
onds again.
Blower Speed Control
Figure 52
NOTE: Blower will only work with fl ame on.
The blower speed control function
is used to adjust the speed of the
blower connected to the Signature
Command System. There are four
speed levels, Off, Low, Medium,
High.
1. Press the FAN button to enter
the blower speed control mode.
The fan icon will start fl ashing.
2. Press the ON/up and OFF/down
button to increase/decrease the
blower speed.
3. Press the fan button again to
confi rm the speed setting. If the
42
®
thermostat func-
®
thermostat op-
®
thermostat
®
thermostat option and return
Figure 52
TOUCH SCREEN REMOTE CONTROL OPERATION
fi replace is on, the blower speed will take effect right
away; if the fi replace is off, the receiver will remember
this setting and the blower is still off (see blower On
Delay and Off Delay in the next section).
4. After the signal is sent, the ON/up and OFF/down but-
tons become fl ame height controller again.
5. When the fan button is fl ashing, slide up and down on
the arrow buttons will turn the blower speed to High
or Off directly without pressing the fan button again to
confi rm.
6. If the blower is turned on using the FAN button, the
blower speed will adjust automatically when using
Smart Mode (See Smart Mode section).
Blower On Delay Time and Off Delay Time Setup
Figure 53
1. Hold the FAN button for 3 sec-
onds until two numbers appear
on the LCD screen. The left
number is blower On Delay
and the right number is blower
Off Delay Time.
2. When the fi rst number is fl ash-
ing, use the ON/up button to
set the desired On Delay Time
from 0 to 15 min.
3. Press the OFF/down button
to jump to the Off Delay Time
setup.
4. When the second number is
fl ashing, use the ON/up button
again to set the desired Off Delay Time from 0 to 15
min.
5. Press the OFF/down button again to fi nish the setup
and the new settings will be transmitted to the receiver.
6. The default settings are 5 minutes for the On Delay
Time and 8 minutes for the Off Delay Time, as shown.
Light Brightness Control
Figure 54
The light brightness control func-
tion is used to adjust the bright-
ness of the light bulbs connected
to the AC module on the Signature
Command System. There are four
light brightness levels defi ned:
Off, Low, Medium, High
1. Press the LIGHT button to en-
ter the light brightness control
mode. The LIGHT icon will
start fl ashing.
2. Press the On/up and OFF/
down buttons to increase/
decrease the light brightness
(Off-Low-Medium-High).
Figure 53
Figure 54
20306742