Vermont Castings KHLDV400PTSCSB Installation And Operating Instructions Manual page 41

Khldv series direct vent gas fireplace
Table of Contents

Advertisement

TOUCH SCREEN REMOTE CONTROL OPERATION
the fl ame height if none of the menu buttons (TIMER,
THERMO, LIGHT, FAN, AUX) are
pressed and fl ashing.
1. Press the ON/up button to turn
on the fi replace. The fl ame icon
on the LCD displays High.
2. Press the OFF/down button to
decrease the fl ame height and
turn off the fi replace. When the
OFF/down button is pressed
for three times, the fl ame icon
changes form High to Medium,
to Low, then to Off.
3. If the OFF button is held for
more than 3 seconds at any
fl ame height, the fi replace will
be turned off and the fl ame icon disappears.
4. Sliding up and down on the arrow buttons can also
turn on or turn off the fi replace.
5. If the fi replace is shut off using the above methods in 3
and 4, all the settings will be re-
membered and will be resumed
next time the fi replace is turned
on (Memory Off).
Timer Mode
Figure 49
Press the TIMER button to enter
timer mode. The fi replace will stay
on for a period of time as specifi ed
by the timer and then be shut off
by the transmitter when the timer
counts down to zero.
1. When the TIMER button is
pressed, the Set Time appears
in the frame of the button and
fl ashes.
2. Use ON/up and OFF/down to increase or decrease the
Set Time in 15 min. increments, between 0:00 to 6:00.
Sliding up and down on the arrow buttons will increase
or decrease the Set Time in 1 hour increments.
3. Push the TIMER button again to confi rm the Set Time,
the transmitter sends an ON signal to turn on the fi re-
place.
4. The fl ashing stops and the ON/up and OFF/down but-
tons become fl ame height controller again. The fl ame
height will then stay as set up by the ON/up and OFF/
down buttons.
5. The TIMER button can be used when the transmitter
is in Manual Mode or in Thermostat Mode. In both
modes, the fi replace will be shut down completely
when the timer counts down to zero.
6. To exit Timer Mode,
20306742
a. Push and hold the TIMER button for 3 seconds Or
b. Use the OFF/down buttons
to decrease the Set Time to
zero Or
c. Slide down on the arrow but-
tons to exit TIMER mode and
shut off the fi replace.
Thermostat Mode
Figure 50
Press the THERMO button to set
the transmitter in thermostat mode.
The transmitter will automatical-
ly turn on the fi replace when the
room temperature is below the set
temperature and turn off the appli-
Figure 48
ance when the room temperature
is above the set temperature within one degree.
1. When the THERMO button is pressed, the Set tem-
perature appears in the frame of the button and fl ash-
es.
2. Use ON/up and OFF/down to increase or decrease
the Set temperature in 1 degree increments, between
45 degrees and 90 degrees. Slide up and down on the
arrow buttons will increase or decrease the Set Tem-
perature in 10 degrees increments.
3. Press the THERMO button again to confi rm the Set
Temperature. The transmitter will send out an On
signal or an Off signal depending on the relationship
between the Set temperature and the Room tempera-
ture.
4. The fl ashing stops and the ON/up and OFF/down but-
tons become fl ame height controller again. The fl ame
height will then stay as set up by the ON/up and OFF/
down buttons.
5. To exit Thermostat Mode:
Figure 49
a. push and hold the THERMO buttons for 3 sec-
onds or
b. slide down on the arrow buttons to exit Thermo-
stat mode and shut off the fi replace.
Smart Mode
Option for Thermostat
Mode
Figure 51
Press and hold the THER-
MO button and the ON/
UP button at the same
time for 3 seconds to tog-
gle between Smart Mode
thermostat and the regu-
lar Thermostat Mode. The
icon "Smart Mode" will ap-
pear under the Set Tem-
perature. The transmitter
KHLDV Series Gas Fireplace
®
Thermostat
®
Figure 50
Smart
Mode
Icon
Figure 51