Vermont Castings KSTDV500(N/P)TSCSB Installation And Operating Instructions Manual

Kstdv series direct vent gas fireplace
Table of Contents

Advertisement

For models purchased after 4/16/15, please see addendum.
KSTDV Series Direct Vent Gas Fireplace

Installation and Operating Instructions

Model: KSTDV500(N/P)TSCSB
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
S
AFETY
DANGER
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall
be installed for the protection of children and
other at risk individuals.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for
future reference.
CERTIFIED
B
ARRIER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
20306543
20306743 11/14 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings KSTDV500(N/P)TSCSB

  • Page 1: Installation And Operating Instructions

    For models purchased after 4/16/15, please see addendum. KSTDV Series Direct Vent Gas Fireplace Installation and Operating Instructions Model: KSTDV500(N/P)TSCSB CERTIFIED AFETY ARRIER WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage.
  • Page 2: Table Of Contents

    CONTENTS KSTDV Series Gas Fireplace Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace! PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fi re hazard and will void the warranty.
  • Page 3: Important Safety Information

    KSTDV Series Gas Fireplace IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fi...
  • Page 4: Code Approval

    IMPORTANT SAFETY INFORMATION & CODE APPROVAL KSTDV Series Gas Fireplace 15. This appliance, when installed, must be electrically IMPORTANT: grounded in accordance with local codes or in the PLEASE READ THE FOLLOWING absence of local codes, with the National Electrical CAREFULLY Code, ANSI/NFPA 70, or the Canadian Electrical Code, It is normal for fi...
  • Page 5: Product Features

    KSTDV Series Gas Fireplace PRODUCT FEATURES PRODUCT SPECIFICATIONS • This appliance has been certifi ed for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting •...
  • Page 6: Fireplace & Framing Dimensions

    FIREPLACE & FRAMING DIMENSIONS KSTDV Series Gas Fireplace 25” Rough (635 mm) Opening Depth 11 ” (292 mm) 23” (584 mm) 1/2” or 5/8” Recessed Nailing Flange 50” (1270 mm) Rough Opening Width Rough Opening 4 ” (108 mm) Height 44 ”...
  • Page 7: Pre-Installation Information

    PRE-INSTALLATION INFORMATION KSTDV Series Gas Fireplace BEFORE YOU START FIREBOX FRAMING Read this homeowner manual thoroughly and follow all Firebox framing can be built before or after the appliance instructions carefully. Inspect all contents for shipping is set in place. Construct fi rebox framing following Figure damage and immediately inform your dealer if any damage 2 for your specifi...
  • Page 8: Fireplace Location

    PRE-INSTALLATION INFORMATION KSTDV Series Gas Fireplace • FIREPLACE LOCATION Vent pipe routing. See Venting section found in this manual for allowable venting confi gurations. Plan for the installation of your appliance. This includes • These units can be installed in a bedroom. See National determining where the unit is to be installed, the vent Fuel Gas Code ANSI Z233.1/NFPA 54 —...
  • Page 9: Clearances

    KSTDV Series Gas Fireplace CLEARANCES CLEARANCES TO COMBUSTIBLES 12” Follow these instructions carefully to ensure safe installation. Failure to follow in struc tions exactly can create a fi re hazard. Noncombustible 6” Material to Top of 16” The appliance cannot be installed on a Standoffs carpet, tile or other combustible material 12”...
  • Page 10: Fireplace Installation

    FIREPLACE INSTALLATION KSTDV Series Gas Fireplace SECURE FIREPLACE TO FLOOR OR FRAM- FINISHING MATERIAL NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to fi nal fi nishing to The fi replace must be secured to the fl oor and/or to framing avoid costly reconstruction.
  • Page 11: Venting Installation

    fl ue pipe penetrates outside wall. • Installation of any component part not manufactured or ** A minimum 1" clearance to combustibles permitted all approved by Vermont Castings Group around fl ue at outside wall • Installation other than permitted by these instructions.
  • Page 12: Installation Planning

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace INSTALLATION PLANNING Never run the vent pipe down. This may There are two basic types of direct-vent installation: cause excessive temperatures which could • Horizontal Termination cause a fi...
  • Page 13: Venting Installation

    † A vent shall not terminate directly above a sidewalk or paved clearances tested and approved by the listing agency. driveway which is located between two single family dwellings and 3. Vermont Castings Group assumes no responsibility for serves both dwellings the improper performance of the appliance when the venting ‡...
  • Page 14: Termination Clearances

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace TERMINATION CLEARANCES Termination clearances for buildings with combustible and non-combustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2"...
  • Page 15: Vertical Sidewall Installation

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace VERTICAL SIDEWALL INSTALLATION NOTE: Sealant is not required to assemble fi replace venting. Do not use silicone sealant at the inner fl ue exhaust connections. Step 1 Locate vent opening on the wall.
  • Page 16: Vertical/Horizontal Termination Confi Gurations

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace VERTICAL/HORIZONTAL TERMINATION CONFIGURATIONS Since it is very important that the venting system maintain its balance between the combustion air intake 24" and the fl ue gas exhaust, certain limitations as to vent (610 mm) confi...
  • Page 17: Below Grade Installation

    For models purchased after 4/16/15, please see addendum. KSTDV Series Gas Fireplace VENTING INSTALLATION • supplied). Refi ll hole with 12" of coarse gravel leaving For each 45° elbow installed in the horizontal run, the a clearance of approximately 4" below snorkel. Figure length of the horizontal run MUST be reduced by 18"...
  • Page 18: Vertical Through-The-Roof Applications

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace • Do not back fi ll around snorkel. • A clearance of at least 4" must be 40' (12 m) Maximum Height maintained between the snorkel and 12' (3.7 m) Minimum Height the soil.
  • Page 19: Installation For Vertical Termination

    For models purchased after 4/16/15, please see addendum. KSTDV Series Gas Fireplace VENTING INSTALLATION For optimal fl ame appearance, a restrictor disk is necessary on straight vertical runs of 10' of more. • Runs may not incorporate elbows. • The disk is part number 56D3027 and is included in installation manual packet.
  • Page 20: Termination Height For Vents Above Flat Or Sloped Roofs

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION KSTDV Series Gas Fireplace 4. Connect a section of pipe and extend up through the " hole. " NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose.
  • Page 21: Gas Pipe Installation

    KSTDV Series Gas Fireplace GAS PIPE INSTALLATION CHECK GAS TYPE Use proper gas type for the fi replace you are installing. If you have confl icting gas type, do not install fi replace. 100 gal. (min) Propane/LP See dealer where you purchased the fi replace for proper External Supply Tank fi...
  • Page 22: Install Gas Supply Line

    GAS PIPE INSTALLATION KSTDV Series Gas Fireplace Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess seal- Only persons licensed to work with gas ant in pipe could result in clogged burner system valves. piping may make the necessary gas We recommend that you install a sediment trap/drip leg in connections to this appliance.
  • Page 23: Checking Gas Pressure And Electrical Installation

    KSTDV Series Gas Fireplace CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION Pressure Inlet CHECK GAS PRESSURE 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fi replace, STOP! Do not install the appliance.
  • Page 24: Junction Box Wiring

    CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION KSTDV Series Gas Fireplace JUNCTION BOX WIRING COMMAND CENTER WALL INSTALLATION 1. This should be done before framing the fi replace. Wire The command center may be mounted on the wall with the receptacle into an electrical circuit. Wire with mini- the use of the SCSWEK Kit (15ft.
  • Page 25: Signature Command Wiring Diagram

    CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION KSTDV Series Gas Fireplace SIGNATURE COMMAND WIRING DIAGRAM Light 300 Watt To Outlet A/C Module Pilot Optional Blower 300 Watt Rear Burner Solenoid 300 Watt Max RF Receiver A/C Module ON/OFF Button Control Board Black / Thermopile Red / Thermopile Sensor...
  • Page 26: Optional Fan/Blower Systems

    OPTIONAL FAN BLOWER SYSTEM KSTDV Series Gas Fireplace BLOTKSTSC SIGNATURE COMMAND Electrical Grounding Instructions: This BLOWER appliance is equipped with a three-prong The BLOTKSTSC Blower Kit requires the SCSACM A/C (grounding) plug for your protection against Module and the TSFRSC remote to install and operate shock hazard and should be plugged directly this kit.
  • Page 27: Final Installation

    KSTDV Series Gas Fireplace FINAL INSTALLATION GLASS FRAME REMOVAL NOTE: You must fi rst remove the safety barrier before Each clamp has a quick spring force. When you remove the glass frame. To remove the barrier, lift reinstalling clamps, keep fi ngers clear. up and pull out until the tabs are clear of their corre- sponding slots on the fi...
  • Page 28: Light & Brick Installation

    FINAL INSTALLATION KSTDV Series Gas Fireplace 6. Place the floor brick panels on the brick supports LIGHT & BRICK INSTALLATION between the hearth bricks. 1. Remove glass frames from fi replace. 7. Place the wall brick panels against the fi rebox walls, 2.
  • Page 29: Log Placement

    KSTDV Series Gas Fireplace FINAL INSTALLATION tine from the left. Position log with the inside face of LOG PLACEMENT the log perpendicular to the middle burner. There will 1. From the back side of the unit (with the controls on your be a slight gap between the left end of the log and log left) and holding log #1 in your left hand with the widest #1 (about 3/8 inch.)
  • Page 30 FINAL INSTALLATION KSTDV Series Gas Fireplace 5. Move to the other side of the unit to place the remaining 8. Hold log #7 with the “Y” pointing away from you and place the log on the notch located on the top of log #3 logs.
  • Page 31: Safety Barrier Installation Instructions

    KSTDV Series Gas Fireplace FINAL INSTALLATION DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. SAFETY BARRIER INSTALLATION INSTRUCTIONS NEVER ALLOW CHILDREN TO TOUCH GLASS. NOTE: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this A barrier designed to reduce the risk of burns from the hot appliance and shall be installed for the protection of...
  • Page 32: Operating Instructions

    KSTDV Series Gas Fireplace OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of lie. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.
  • Page 33: Operating Instructions

    KSTDV Series Gas Fireplace OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With fi ve (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell gas, STOP! Follow "B"...
  • Page 34: Features

    KSTDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS To Thermopile FEATURES RF Receiver ON/OFF To Sensor Command Center To Sparker • Easy Access Function Operation and System Confi g- uration NG/LP • Operation Confi rmation/Fault Diagnostic Indications Conversion (LED/Buzzer) •...
  • Page 35: Key Combinations For System Settings

    KSTDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS Either mode benefi ts from the instantaneous battery back- Remote Transmitter Learn Function (Default OFF) up, so you never have to worry about a power outage. 1. The RF receiver button located on the Control Board NOTE: The Signature Command System comes standard must be in the on position before the learn function can in the Intermittent Pilot mode, so you must follow the in-...
  • Page 36: Functions/Operation

    KSTDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS 2. Press the OFF button to decrease fl ame height. The fi rst FUNCTIONS/OPERATION (with Command two presses will decrease the fl ame height to medium Center) and low. Turning on the fi replace 3.
  • Page 37: Touch Screen Remote Transmitter Operation

    TOUCH SCREEN REMOTE CONTROL OPERATION KSTDV Series Gas Fireplace Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room temperature before accurate room tempera- tures are displayed. If the transmitter is acti- vated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LCD display.
  • Page 38: Functions And Operations

    TOUCH SCREEN REMOTE CONTROL OPERATION KSTDV Series Gas Fireplace Command Center Setting Privacy Code on Transmitter: Master Switch Figure 50 The remote transmitter privacy code is preset in facto- ry. In the event of activation or interference from other nearby transmissions, change the code using the following procedures (learn function must be performed after changing the code):...
  • Page 39 KSTDV Series Gas Fireplace TOUCH SCREEN REMOTE CONTROL OPERATION THERMO, LIGHT, FAN, AUX) are pressed and fl ashing. a. Push and hold the TIMER button for 3 seconds Or b. Use the OFF/down buttons to decrease the Set 1. Press the ON/up button to turn Time to zero Or on the fi...
  • Page 40 TOUCH SCREEN REMOTE CONTROL OPERATION KSTDV Series Gas Fireplace just the fl ame height according to the difference between fi replace is off, the receiver will remember this setting the Set temperature and the Room temperature. There is and the blower is still off (see blower On Delay and Off no manual fl...
  • Page 41: Safety Features

    KSTDV Series Gas Fireplace TOUCH SCREEN REMOTE CONTROL OPERATION 3. Press the light button again to confi rm the setting. The 2. When the current setting is B), pressing TIMER button new setting will be transmitted to the receiver. and THERMO button at the same time for 3 seconds will switch to A) Mode.
  • Page 42: Using The Mounting Base

    TOUCH SCREEN REMOTE CONTROL OPERATION KSTDV Series Gas Fireplace  USING THE MOUNTING BASE The transmitter comes with a mounting base which allows you to hang the transmitter on the wall. 1. Secure the mounting base on the wall with supplied screws.
  • Page 43: Cleaning And Maintenance

    CLEANING AND MAINTENANCE KSTDV Series Gas Fireplace Sensor Turn off gas before servicing fi replace. It is recommended that a qualifi ed service Thermopile technician perform these check-ups at the beginning of each heating season BURNER, PILOT AND CONTROL COMPART- MENT Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at...
  • Page 44: Vent System

    KSTDV Series Gas Fireplace CLEANING AND MAINTENANCE VENT SYSTEM LOGS The fi replace and venting system should be inspected Leave logs installed in the fi replace for cleaning. Vacuum before initial use and at least annually by a qualifi ed fi eld surface of the logs with a brush attachment.
  • Page 45: Troubleshooting

    KSTDV Series Gas Fireplace TROUBLESHOOTING SIGNATURE COMMAND SYSTEM ACTION OPERATION FAULT DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 46: Replacement Parts

    REPLACEMENT PARTS KSTDV Series Gas Fireplace FIREBOX COMPONENTS AND ACCESSORIES Item Description Qty. KSTDV500 Bulb (100 Watt) 73D0020 Bulb Socket 73D4521 Glass Frame Assembly 73D0159 Junction Box Assembly (not shown) 26D2128 Light Lens 73D4057K Access Doors 73D3258 Front Cover 73D4524 Screens 73D0017 Screen Rod...
  • Page 47: Signature Command System Components

    REPLACEMENT PARTS KSTDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM COMPONENTS 29, 30 20306743...
  • Page 48 REPLACEMENT PARTS KSTDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM COMPONENTS Item Description Qty. KSTDV500NTSC KSTDV500PTSC Gas Valve Assembly 80D0001 80D0002 Pilot Assembly 80D0039 80D0040 Control Box 80D0037 80D0038 AC Module SCSACM SCSACM Command Center 80D0005 80D0005 Tube, Tee to Front Burner 73D4062 73D4062 Tube between Tees...
  • Page 49: Logs

    REPLACEMENT PARTS KSTDV Series Gas Fireplace LOGS Item Description Qty. KSTDV500 Log #1 73D4090 Log #2 73D4091 Log #3 73D4092 Log #4 73D4093 Log #5 73D4094 Log #6 73D4095 Log #7 73D4096 Log #8 73D4097 20306743...
  • Page 50: Accessories

    REPLACEMENT PARTS KSTDV Series Gas Fireplace ACCESSORIES Standard Herringbone Herringbone Cottage Cottage Tavern Vintage Ref. Description Qty. Clay Brown Brown English Brick, Wall Eng. Side 73D4127 73D4132 73D4149 Brick, Wall Air Side 73D4128 73D4133 73D4150 Brick, Floor 73D4129 73D4134 73D4151 Brick, Front, Left 73D4130 73D4135...
  • Page 51: Vent Components

    For models purchased after 4/16/15, please see addendum. REPLACEMENT PARTS KSTDV Series Gas Fireplace VENT COMPONENTS 20306743...
  • Page 52 For models purchased after 4/16/15, please see addendum. REPLACEMENT PARTS KSTDV Series Gas Fireplace VENT COMPONENTS FOR 5" 8" Current Duravent Duravent or Vermont or Vermont Qty./ Castings Group Castings Group Selkirk Metal-Fab Item Box Description Part no. Part no. Part no.
  • Page 53 KSTDV Series Gas Fireplace 20306743...
  • Page 54: Massachusetts Residents Only

    MASSACHUSETTS RESIDENTS ONLY KSTDV Series Gas Fireplace Please read and follow these special requirements 2. Approved Carbon Monoxide Detectors. Each carbon NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fi tter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts.
  • Page 55: Warranty

    This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fi tness for purpose and of all other obligations or liabilities. Vermont Castings Group does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you.
  • Page 56: Effi Ciencies

    KSTDV Series Gas Fireplace EFFICIENCY RATINGS EnerGuide Ratings D.O.E. Model Fireplace Effi ciency (AFUE) KSTDV500NTSC 77.30% 67.40% KSTDV500PTSC 74.30% 66.35% 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com 20306743...
  • Page 57: Installation Instructions

    CAUTION The information in this instruction manual supersedes the venting information located in the owners manual shipped All Vermont Castings Group Direct Vent Fireplaces have with your fireplace. been tested and approved to ANSI / CSA Standards and The following termination kits can only be used with will operate safely when installed in accordance with this Vermont Castings Group Direct Vent fireplaces.
  • Page 58 5" x 8" DVP Termination Kit IMPORTANT SAFETY INFORMATION PRE-INSTALLATION INFORMATION • The termination cap MUST be vented directly to the Before You Start outside. The termination kit MUST NEVER be con- Plan your installation. Set the unit in place and survey how nected to a chimney flue(s) servicing a separate sol- to best vent the unit.
  • Page 59 5" x 8" DVP Termination Kit Assemble Pipe Sections ATTENTION Insert the inner flue of section A into the flared inner flue of section B. (See figure 2). For use on VCG fireplaces certified to ANSI Z21.50/CSA 2.22 and ANSI Z21.88/CSA 2.33 standards. Start the outer flue of section A over the outer flue of section B.
  • Page 60 5" x 8" DVP Termination Kit Assemble Slip Sections Make sure the seams are not aligned to prevent unintention- al disconnection. The outer flue of the slip section should slide over the outer flue of the pipe section and into (inner flue) the last pipe section (see Figure 5) .
  • Page 61 5" x 8" DVP Termination Kit Secure the Vent Sections Vertical secitons of pipe must be supported every 8 ft. after the 25 ft. maximum unsupported rise. The vent support or plumber’s strap (spaced 120° apart) may be used to do this (see Figure 7).
  • Page 62 5" x 8" DVP Termination Kit Attach slip section of cap to last vent section. Maintain 1-1/2 in. overlap between slip and vent sections. Secure termination cap to exterior wall using provided holes and fasteners. Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base.
  • Page 63 5" x 8" DVP Termination Kit DVP-RVTK, DVP-RVTM, DVP-HVTK 4. A wall square firestop MUST BE installed if the vent passes through a ceiling or exterior combustible wall. HORIZONTAL TERMINATION KIT Cut a 10" wide x 10" high (254 x 254 mm) opening Installation Instructions through the wall or framing.
  • Page 64 5" x 8" DVP Termination Kit WARNING Refer to your fireplace Homeowner’s Manual for the Cutout On Vinyl minimum and maximum venting requirements of your fireplace and for approved horizontal vent termination locations prior to installation. Failure to do so may cause fire hazard.
  • Page 65 5" x 8" DVP Termination Kit 6. Slide the 8" flex pipe over the outer pipe of the DVP flex starter that is attached to the unit. Secure the Exterior Wall Sheeting flex pipe to the outer of the DVP flex starter with one (1) large band clamp and three (3) self tapping #10 J-channel (around Framing...
  • Page 66 5" x 8" DVP Termination Kit VERTICAL THROUGH-ROOF FLEX UL1777 Secure Screws Flex Vent VENTING (3 Places Equidistant Just Above Gear 1. Flexible UL1777 listed venting may be used in any Clamp) venting application where rigid direct vent components can be used. All restrictions, clearances and 2"...
  • Page 67 5" x 8" DVP Termination Kit N O T E : F l e x v e n t p i p e s p a c e r s : R e f e r t o manufacturer ’s specifications for correct positioning of the spacer springs to maintain proper distance between inside and outside pipe.
  • Page 68 5" x 8" DVP Termination Kit Flat Ceiling Installation Roof Support • Remove one shield from box. 1. Fasten the roof support to the roof sheathing using 2" wood screws provided. Figure 21. Note: Cut previously installed batt insulation to make Ensure that the termination pipe is centered and room for the attic insulation shield.
  • Page 69 5" x 8" DVP Termination Kit Install Roof Flashing Caulk the gap between the roof flashing and the outside diameter of the pipe. Caulk the perimeter of the flashing To install roof flashing see Figures 24 and 25. where it contacts the roof surface. For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 23) .
  • Page 70 5" x 8" DVP Termination Kit Install Vertical Termination Cap Attaching Flexible Venting to Vertical To attach the vertical termination cap, slide the inner col- Termination Kit lar of the cap into the inner flue of the vent section and 1.
  • Page 71 5" x 8" DVP Termination Kit Termination Storm Collar Roof Support Rigid Pipe Flashing Refer to Figures Length 5 & 6 Rigid Pipe Secure Screws Length (3 Places Equidistant Flex Adapter Just Above Gear Outer Clamp) Flex Adapter Inner Gear Flex Adapter 2"...
  • Page 72 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...

This manual is also suitable for:

Kstdv500ntscKstdv500ptsc

Table of Contents