Vermont Castings 300DVB(N/P)(V/SC)7SB Installation And Operating Instructions Manual

Dvb series direct vent gas fireplace
Table of Contents

Advertisement

For models purchased after 4/16/15, please see addendum.
DVB Series Direct Vent Gas Fireplace

Installation and Operating Instructions

Models:
300DVB(N/P)(V/SC)7SB, 400DVB(N/P)(V/SC)7SB,
500DVB(N/P)(V/SC)7SB
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
S
AFETY
DANGER
547050
DVB7 cover
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
DANGER
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
CERTIFIED
B
ARRIER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
20306740 11/14 Rev. 1
Un panneau vitré chaud peut
causer des brûlures.
Laissez refroidir le panneau

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings 300DVB(N/P)(V/SC)7SB

  • Page 1: Installation And Operating Instructions

    For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace Installation and Operating Instructions Models: 300DVB(N/P)(V/SC)7SB, 400DVB(N/P)(V/SC)7SB, 500DVB(N/P)(V/SC)7SB WARNING: CERTIFIED FIRE OR EXPLOSION HAZARD AFETY ARRIER Failure to follow safety warnings exactly could result in serious injury, death or property damage.
  • Page 2: Table Of Contents

    DVB Series Direct Vent Gas Fireplace CONTENTS Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation.
  • Page 3: Important Safety Information

    DVB Series Direct Vent Gas Fireplace IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.
  • Page 4: Code Approval

    DVB Series Direct Vent Gas Fireplace IMPORTANT SAFETY INFORMATION 12. Do not use this fireplace to cook food or burn paper or IMPORTANT: other objects. PLEASE READ THE FOLLOWING 13. Never place anything on top of fireplace. CAREFULLY 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace.
  • Page 5: Pre-Installation Information

    DVB Series Direct Vent Gas Fireplace PRE-INSTALLATION INFORMATION PRODUCT SPECIFICATIONS GAS SPECIFICATIONS & ORIFICE SIZE • This appliance has been certified for use with either natural or propane gas. Refer to appropriate data Max. Min. Orifice plates. Model Fuel Input Input Size •...
  • Page 6: Fireplace & Framing Dimensions

    DVB Series Direct Vent Gas Fireplace PRE-INSTALLATION INFORMATION FIREPLACE AND FRAMING DIMENSIONS Min. Rough Opening Depth 5/8” 1/2” 1/2” 1/2” or 5/8” 5/8” O - Min. Rough Opening Width Min. Rough Opening Height 1/2” 5/8" Figure 2 - 3¹⁄₂” Fireplace and Framing Dimensions 8¹⁄₄”...
  • Page 7: Firebox Framing

    DVB Series Direct Vent Gas Fireplace PRE-INSTALLATION INFORMATION FIREBOX FRAMING Do not fill spaces around firebox with Firebox framing can be built before or after the appliance insulation or other materials. This could is set in place. Refer to Figure 2 for fireplace and framing cause a fire.
  • Page 8: Clearance To Combustibles

    FP2248 NOTE: The Vermont Castings Group Barrington Cabinet mantel clearances Mantel Model series BWC300, BWC400 and BWC500 are specially designed to comply with all mantel tempera- ture requirements.
  • Page 9: Secure Fireplace To Floor Or Framing

    DVB Series Direct Vent Gas Fireplace PRE-INSTALLATION INFORMATION SECURE FIREPLACE TO FLOOR or FRAMING The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 10: Venting Installation

    For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace VENTING INSTALLATION OPTIONAL TOP VENT APPLICATION After conversion to top vent configuration, The appliance is shipped as a rear vent unit. If the installa- the 4” (102 mm) flue pipe should be tion layout requires the unit to be a top vent configuration concentric within the 6 ⁄...
  • Page 11: Installation Precautions

    Failure to do so could result in serious • injury, property damage or loss of life. Only Vermont Castings Group venting compo- nents specifically approved and labelled for this Operation of improperly installed and fireplace may be used.
  • Page 12: Termination Location

    † A vent shall not terminate directly above a sidewalk or paved clearances tested and approved by the listing agency. driveway which is located between two single family dwellings and 3. Vermont Castings Group assumes no responsibility for serves both dwellings the improper performance of the appliance when the venting  Only permitted if veranda, porch, deck or balcony is fully open on a system does not meet these requirements.
  • Page 13: Termination Clearances

    National Fuel Code ANSI Z223.1/NFPA 54. dure must be performed on the vent side. Only venting components manufactured or approved by Vermont Castings Group may be used in Direct Vent sys- tems. Canadian Installations The venting system must be installed in accordance with the current CSA-B149.1 installation code.
  • Page 14: Twist Lock Pipes

    For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace VENTING INSTALLATION TWIST LOCK PIPES HOW TO USE THE VENT GRAPH When using twist lock pipe it is not necessary to use seal- The Vent Graph should be read in conjunction with the ant on the joints.
  • Page 15: Venting Clearances

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION DVB Series Direct Vent Gas Fireplace This fireplace must be vented to the Horizontal sections of this vent system outside. The venting system must NEVER require a minimum of 3” clearances to be attached to a chimney serving a separate combustibles at the top of the flue and 1”...
  • Page 16: Rear Wall Vent Applications & Installation

    (244 mm) Min. behind the appliance. • Only Vermont Castings Group venting components are approved to be used in these applications (Refer 95/8” (244 mm) to ‘Venting Components’ listed for different installation Min.
  • Page 17: Top Vent Sidewall Applications & Installation

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION DVB Series Direct Vent Gas Fireplace Finish Wall Vent Rise Termination FP1472 Figure 20 - There must be a 1/2" rise per foot length TOP VENT SIDEWALL APPLICATION Figure 18 - FP2294 NOTE: For all top vent installations where a 90°...
  • Page 18 For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace VENTING INSTALLATION When installing the appliance as a rear vent unit, the • The maximum number of elbow degrees in a system is 90° or 45° Transition Elbow attached directly to the 270°.
  • Page 19: Vertical Sidewall Installation

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION DVB Series Direct Vent Gas Fireplace VERTICAL SIDEWALL INSTALLATION - TWIST LOCK PIPE Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation.
  • Page 20 For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace VENTING INSTALLATION Step 7 Guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (51 mm). Secure the termina- 4”...
  • Page 21: Below Grade Installations

    For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION DVB Series Direct Vent Gas Fireplace BELOW GRADE INSTALLATIONS 6. Slide the snorkel into the vent pipes and secure to the wall. When it is not possible to meet the required vent terminal 7.
  • Page 22: Installation

    For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace VENTING INSTALLATION VERTICAL THROUGH-THE-ROOF INSTALLATION NOTE: For all top vent straight vertical through-the-roof Max.Height installations greater than 12’ (3.7 m), install the supplied 40’ (12.2. m) cross-bar flue restrictor onto the top edge of the firebox Min.
  • Page 23 For models purchased after 4/16/15, please see addendum. VENTING INSTALLATION DVB Series Direct Vent Gas Fireplace 10. Add additional vent lengths for proper height. Figure Horizontal Overhang 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install. 2 ft.
  • Page 24: Fireplace Installation

    DVB Series Direct Vent Gas Fireplace FIREPLACE INSTALLATION A qualified installer or service person must connect appliance to gas supply. Follow 100 lb. (min) all local codes. External Propane/LP Regulator Supply Tank CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace.
  • Page 25: Installing Gas Piping

    DVB Series Direct Vent Gas Fireplace FIREPLACE INSTALLATION A manual shutoff valve must be installed Only persons licensed to work with gas upstream of the appliance. Union tee piping may make the necessary gas and plugged 1/8” NPT pressure tapping connections to this appliance.
  • Page 26: Installation - Millivolt

    DVB Series Direct Vent Gas Fireplace INSTALLATION - MILLIVOLT MILLIVOLT CHECK GAS PRESSURE ELECTRICAL WIRING 1. Check gas type. The gas supply must be the same as This fireplace will work without any electrical supply. Elec- stated on the appliance’s rating decal. If the gas sup- tricity is only needed to operate blower.
  • Page 27: Remote Wall Switch Installation

    DVB Series Direct Vent Gas Fireplace INSTALLATION - MILLIVOLT REMOTE WALL MOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. Do not connect wall switch to (110 V) wire may be used with this appliance. Attach the wall circuit.
  • Page 28: Operating Instructions - Millivolt

    DVB Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 29: Lighting Pilot

    DVB Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - MILLIVOLT LIGHTING THE PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: DO NOT spray solution onto •...
  • Page 30: Lighting Burner

    DVB Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - MILLIVOLT LIGHTING BURNER MAIN BURNER SWITCH The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 31: Installation - Signature Command System

    DVB Series Direct Vent Gas Fireplace INSTALLATION - SIGNATURE COMMAND CHECK GAS PRESSURE ELECTRICAL INSTALLATION 1. Check gas type. The gas supply must be the same as 1. This fireplace is equipped with the Signature Control stated on the appliance’s rating decal. If the gas supply valve which operates on 6 volts.
  • Page 32: Junction Box Wiring

    DVB Series Direct Vent Gas Fireplace INSTALLATION - SIGNATURE COMMAND JUNCTION BOX WIRING WALL SWITCH INSTALLATION 1. This should be done before framing the fireplace. Wire The wall switch wire connection is located off the 2 ft. wire the receptacle into an electrical circuit. Wire with mini- harness from the control box to the command center.
  • Page 33: Signature Command Wiring Diagram

    DVB Series Direct Vent Gas Fireplace INSTALLATION - SIGNATURE COMMAND Optional To Junction Box AC Module in Fireplace Pilot Optional White Light Black Optional White Blower Black White Optional Black Aux. Green Connector Pin To Control Board Input 300 Watt Max. Each Optional A/C Module Replaces 6V Adapter When Used RF Receiver...
  • Page 34: Optional Fan/Blower Systems

    DVB Series Direct Vent Gas Fireplace INSTALLATION - SIGNATURE COMMAND Electrical Grounding Instructions: This Electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against Main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical into a properly grounded three-prong...
  • Page 35 DVB Series Direct Vent Gas Fireplace INSTALLATION - SIGNATURE COMMAND BLOT AUTOMATIC THERMOSTAT BLOWER Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.
  • Page 36: Operating Instructions - Signature Command

    DVB Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A.
  • Page 37: Operating Instructions

    DVB Series Direct Vent Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 38: Features

    DVB Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION FEATURES BATTERY INSTALLATION The Command Center uses four (4) "AA" batteries as Command Center back up for power outages. The system can operate for • approximately six (6) months on battery power. Easy Access Function Operation and System Configuration To Install Batteries (not included):...
  • Page 39: System Configuration/Setup

    DVB Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION SYSTEM CONFIGURATION/SETUP tinue to operate unattended. 2. When the master switch is in the ON position (“-”), All System configuration/setup is done on the Command pressing the ON button and the OFF button on the Center.
  • Page 40: Functions/Operation

    DVB Series Direct Vent Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION Command Center Operations: FUNCTIONS/OPERATION Turning on the fireplace The following functions are available on the Command Center. 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn Function LED Indication on wall switch.
  • Page 41: Final Installation

    DVB Series Direct Vent Gas Fireplace FINAL INSTALLATION GLASS FRAME REMOVAL DANGER NOTE: If the safety barrier is in place, you must first remove it before you remove the glass frame. To remove the barrier, simply lift up and pull out until the tabs are HOT GLASS WILL clear of their corresponding slots on the firebox.
  • Page 42: Rockwool Placement

    DVB Series Direct Vent Gas Fireplace FINAL INSTALLATION ROCK WOOL PLACEMENT LOG PLACEMENT 1. For best results in flame appearance and operation: 1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins on the bars. a.
  • Page 43: Safety Screen Barrier Installation

    DVB Series Direct Vent Gas Fireplace FINAL INSTALLATION SAFETY BARRIER INSTALLATION DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS NOTE: A barrier designed to reduce the risk of burns from UNTIL COOLED. the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other NEVER ALLOW CHILDREN at risk individuals.
  • Page 44: Cleaning And Maintenance

    DVB Series Direct Vent Gas Fireplace CLEANING and MAINTENANCE BURNER FLAME PILOT FLAME The flames from the burner should be visually checked The flames from the pilot should be visually checked as as soon as the heater is installed and periodically during soon as the heater is installed and periodically during normal operation.
  • Page 45: Vent System

    DVB Series Direct Vent Gas Fireplace CLEANING and MAINTENANCE VENT SYSTEM LOGS The fireplace and venting system should be inspected Leave logs installed in the fireplace for cleaning. Vacuum before initial use and at least annually by a qualified surface of the logs with a brush attachment. If logs must field service person.
  • Page 46: Troubleshooting

    DVB Series Direct Vent Gas Fireplace TROUBLESHOOTING STANDING PILOT IGNITION SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will A. Wire disconnected. A. Open door and check to make sure wire is connected to ignitor. not light pilot after B. Defective ignitor. B.
  • Page 47: Signature Command System

    DVB Series Direct Vent Gas Fireplace TROUBLESHOOTING SIGNATURE COMMAND SYSTEM ACTION OPERATION FAULT DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 48: Replacement Parts

    DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS FIREBOX COMPONENTS 540701 DVB parts 20306740...
  • Page 49 DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS FIREBOX COMPONENTS Item Description Qty. 300DVB 400DVB 500DVB Standard Features Junction Box 26D2128K 26D2128K 26D2128K Black Louver 54D0246 26D0695 26D0697 Glass Frame Assembly 54D0294K 54D0195K 54D0340K Safety Screen Barrier 20306705K 20306695K 20306701K Factory Installed Options Black Louver 54D0249K...
  • Page 50: Logs

    DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS LOGS Ref. Description Qty. 300DVB 400DVB 500DVB Rear Log #1 54D0122 54D0117 54D0331 Bottom Left Log #2 54D0123 54D0118 54D0358 Bottom Right Log #3 54D0124 54D0119 54D0359 Top Log #4 54D0125 54D0120 54D0552 540701 DVB log parts...
  • Page 51: Standing Pilot Millivolt Control

    DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL 11,12,13,14 540701 DVB millivolt parts 20306740...
  • Page 52 DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL Item Description Qty. 300DVBNV7 300DVBPV7 400DVBNV7 400DVBPV7 500DVBNV7 500DVBPV7 Gas Valve Assy. 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019 Replacement Thermocouple 37D1067 37D1067 37D1067...
  • Page 53: Signature Command System

    DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 13,14,15,16,17 540701 SC parts 20306740...
  • Page 54 DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM Item Description Qty. 300DVBNS7 300DVBPS7 400DVBNS7 400DVBPS7 500DVBNS7 500DVBPS7 Gas Valve Assy. 80D0001 80D0002 80D0001 80D0002 80D0001 80D0002 Pilot Assembly 80D0006 80D0007 80D0006 80D0007 80D0006 80D0007 Control Box 80D0018 80D0019 80D0018 80D0019...
  • Page 55: Vertical Venting Components

    For models purchased after 4/16/15, please see addendum. REPLACEMENT PARTS DVB Series Direct Vent Gas Fireplace VERTICAL VENTING Description Model Number Vertical Vent Termination Kits Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm 7TDVSKVA*...
  • Page 56: Horizontal Venting Components

    For models purchased after 4/16/15, please see addendum. DVB Series Direct Vent Gas Fireplace REPLACEMENT PARTS HORIZONTAL VENTING Description Model Number Horizontal Vent Termination Kits Up and Out Side Wall Termination Kit, includes 12” to 16” Adjustable Termination Pipe, 7TBLSCTK 90°...
  • Page 57: Venting Components

    For models purchased after 4/16/15, please see addendum. VENTING COMPONENTS DVB Series Direct Vent Gas Fireplace VENT COMPONENTS FOR 4" X 6 ⁄ " (Duravent, Selkirk); Old Duravent 4" x 6 ⁄ " (Metal-Fab) Current Duravent or VCG Selkirk Metal-Fab Item Box Description or VCG Part No.
  • Page 58: Massachusetts Residents Only

    MASSACHUSETTS RESIDENTS ONLY DVB Series Direct Vent Gas Fireplace Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS 2. Approved Carbon Monoxide Detectors. Each carbon This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts.
  • Page 59: Warranty

    This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchant- ability of fitness for purpose and of all other obligations or liabilities. Vermont Castings Group does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. It states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you.
  • Page 60: Efficiencies

    Based on CSA P.4.1-09 EFFICIENCY RATINGS ENERGUIDE RATINGS FIREPLACE EFFICIENCY MODEL PERCENTAGE 300DVBNV7 57.9 300DVBPV7 53.8 Recherchez dans la brochure 300DVBNSC7 61.8 les caractéristique de rendement 300DVBPSC7 55.7 énergétique de foyer au gaz 400DVBNV7 58.4 Énerguide 400DVBPV7 58.5 Based on CSA P.4.1-09 Selon CSA P.4.1-09 400DVBNSC7 61.1...
  • Page 61: Installation Instructions

    Models: SLP-RVTK, SLP-RVTM, SLP-HVTK, SLP-HSFTK, SLP-TRFK The following termination kits can only be used with CAUTION Vermont Castings Group Direct Vent fireplaces. Check and verify your fireplace model. All Vermont Castings Group Direct Vent Fireplaces have been tested and approved to ANSI/CSA Standards and...
  • Page 62 4" x 6 ⁄ " SLP Termination Kit PRE-INSTALLATION INFORMATION PRE-INSTALLATION INFORMATION IMPORTANT SAFETY INFORMATION Before You Start • The termination cap MUST be vented directly to the outside. The termination kit MUST NEVER be con- Plan your installation. Set the unit in place and survey how nected to a chimney flue(s) servicing a separate sol- to best vent the unit.
  • Page 63 4" x 6 ⁄ " SLP Termination Kit PRE-INSTALLATION INFORMATION Attach the First Vent Component to SLP Starting ATTENTION Collars To attach the first vent component to the starting collars For use on VCG fireplaces certified to ANSI Z21.50/CSA of the appliance: 2.22 and ANSI Z21.88/CSA 2.33 standards.
  • Page 64 4" x 6 ⁄ " SLP Termination Kit ADDITIONAL ASSEMBLY INSTRUCTIONS Make sure the seams are not aligned to prevent DVP & SLP VENT PIPE unintentional disconnection. Assemble Slip Sections The outer flue of the slip section should slide over the outer flue of the pipe section and into (inner flue) the last pipe section (see Figure 4).
  • Page 65 4" x 6 ⁄ " SLP Termination Kit Secure the Vent Sections Vertical sections of SLP pipe must be supported every 8 ft. The SLP firestop includes tabs that may be used to secure vertical sections. The vent support or plumber’s strap (spaced 120° apart) may be used to secure the vertical sections of pipe (see Figure 5).
  • Page 66 4" x 6 ⁄ " SLP Termination Kit Divert Roof Run-off HORIZONTAL TERMINATION CAP VCG/HHT recommends, where excessive water run-off is possible, use of one of the two options shown in Figure WARNING 10 to prevent water running off the roof and onto/into the horizontal termination cap.
  • Page 67 4" x 6 ⁄ " SLP Termination Kit SLP-RVTK, SLP-RVTM, SLP-HVTK - SLP-RVTK, SLP-RVTM, SLP-HVTK: HORIZONTAL TERMINATION KIT During shipping, the SLP6A is slid over the SLP6 to make an adjustable pipe. In some installations, you may want Installation Instructions to use only the SLP6 (for instances in which the adjustable Figure 11 pipe is too long for installation.) Otherwise, adjust pipe to...
  • Page 68 4" x 6 ⁄ " SLP Termination Kit SLP-HSFTK HORIZONTAL WARNING TERMINATION KIT Figure 13 Refer to your fireplace Homeowner’s Manual for the Installation Instructions minimum and maximum venting requirements of your Set the unit in place and survey how best to vent the unit. fireplace and for approved horizontal vent termination A wall square firestop MUST BE installed if the vent passes locations prior to installation.
  • Page 69: Horizontal Termination Kit

    4" x 6 ⁄ " SLP Termination Kit Install the termination cap to the exterior wall with four Exterior Wall (4) #8 x 3" screws provided. In some installations the Sheeting flexible vent may need to pass through the SLP-FS wall J-channel (around Framing shield firestop.
  • Page 70 4" x 6 ⁄ " SLP Termination Kit VERTICAL THROUGH-ROOF UL1777 Secure Screws Flex Vent (3 Places Equidistant FLEX VENTING Just Above Gear 1. Flexible UL1777 listed venting may be used in any Clamp) venting application where rigid direct vent components can be used.
  • Page 71 4" x 6 ⁄ " SLP Termination Kit Install the Ceiling Firestop • Frame an opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent system penetrates a ceiling/floor (see Figure 3) • Frame the area with the same sized lumber as used in ceiling/floor joist.
  • Page 72 4" x 6 ⁄ " SLP Termination Kit 1. Flat Ceiling Installation Roof Support • Remove one shield from box. 1. Fasten the roof support to the roof sheathing using 2” wood screws provided. Figure 6. Ensure that the NOTE: Cut previously installed batt insulation to make termination pipe is centered and has a minimum of room for the attic insulation shield.
  • Page 73 4" x 6 ⁄ " SLP Termination Kit Install Roof Flashing Caulk the gap between the roof flashing and the outside diameter of the pipe. Caulk the perimeter of the flashing To install roof flashing see Figures 9 and 10. where it contacts the roof surface.
  • Page 74 4" x 6 ⁄ " SLP Termination Kit Attaching Flexible Venting to Vertical Install Vertical Termination Cap Termination Kit To attach the vertical termination cap, slide the inner col- lar of the cap into the inner flue of the vent section and 1.
  • Page 75 4" x 6 ⁄ " SLP Termination Kit Termination Storm Collar Roof Support Rigid Pipe Flashing Refer to Figures Length 5 & 6 Rigid Pipe Secure Screws Length (3 Places Equidistant Flex Adapter Just Above Gear Outer Clamp) Flex Adapter Inner Gear Flex Adapter...
  • Page 76 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...