KHLDV Series Gas Fireplace
14. Do not use any solid fuels (wood, coal, paper, card-
board, etc.) in this fi replace. Use only the gas type
indicated on rating plate.
15. This appliance, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
16. Do not obstruct the fl ow of combustion and ventilation
air in any way. Provide adequate clearances around
air openings into the combustion chamber along with
adequate accessibility clearance for servicing and
proper operation.
17. When the appliance is installed directly on carpeting,
tile or other combustible material other than wood
fl ooring, you must set appliance on a metal or wood
panel or hearth pad extending the full width and depth
of the appliance.
18. Do not use fi replace if any part has been exposed to
or has been under water. Immediately call a qualifi ed
service technician to inspect the appliance and replace
any part of the control system and any gas control
which as been submerged in water.
19. Do not operate fi replace if any log is broken.
20. Do not use a blower insert, heat exchanger insert, or
any other accessory not approved for use with this
fi replace.
21. Do not operate the fi replace with glass door removed,
cracked, or broken.

CODE APPROVAL

Direct Vent type appliances draw all combustion air from
outside of the dwelling through the vent pipe.
These appliances have been tested by CSA and found to
comply with the established standards for DIRECT VENT
GAS FIREPLACE HEATERS in the USA and Canada as
follows:
LISTED VENTED GAS FIREPLACE HEATER
TESTED TO: ANSI Z21.88-2009 / CSA 2.33-2009
STANDARDS
A manufactured home (USA only) or mobile home OEM
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part
3280, or when such a standard is not applicable, the
Standard for Manufactured Home Installations, ANSI/
NCSBCS A225.1, or Standard for Gas Equipped Rec-
reational Vehicles and Mobile Housing, CSA Z240.4.
4
IMPORTANT SAFETY INFORMATION and CODE APPROVAL
It is normal for fi replaces fabricated of steel to give off
some expansion and/or contraction noises during the
start up or cool down cycle. Similar noises are found with
your furnace heat exchanger or car engine.
It is not unusual for gas fi replaces to give off some
odor the first time it is burned. This is due to the
manufacturing process.
Please ensure that your room is well ventilated
It is recommended that you burn your fi replace for at
least ten (10) hours the fi rst time you use it. Place the
fan switch in the "OFF" position during this time.
IMPORTANT:
PLEASE READ THE FOLLOWING
CAREFULLY
IMPORTANT:
PLEASE READ THE FOLLOWING
CAREFULLY
during burn off — open all windows.
Never connect unit to private (non-util-
ity) gas wells. This gas is commonly
known as wellhead gas.
20306742