Technical Parameters - Baxi EcoBlue System 12 Installation And Service Manual

Gas fired wall mounted condensing system boiler
Hide thumbs Also See for EcoBlue System 12:
Table of Contents

Advertisement

3
Technical Specifications
Technical parameters for boiler space heaters
Baxi EcoBlue System ErP
Condensing boiler
Low-temperature boiler
B1 boiler
Cogeneration space heater
Combination heater
Rated heat output
Useful heat output at rated heat output
and high temperature regime
Useful heat output at 30% of rated heat
output and low temperature regime
Seasonal space heating energy efficiency
Useful efficiency at rated heat output and
high temperature regime
Useful efficiency at 30% of rated heat
output and low temperature regime
Auxiliary electricity consumption
Full load
Part load
Standby mode
Other items
Standby heat loss
Ignition burner power consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature (at
heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
16
EcoBlue System
(1)
Prated
P
4
P
1
(1)
s
4
(2)
1
(1)
elmax
elmin
P
SB
P
stby
P
ign
Q
HE
L
WA
NO
X
3.2

Technical Parameters

12
15
Yes
Yes
No
No
No
No
No
No
No
No
kW
12
15
kW
12.0
15.0
kW
4.0
5.0
%
93
93
%
88.1
88.0
%
98.2
98.1
kW
0.035
0.040
kW
0.014
0.014
kW
0.003
0.003
kW
0.035
0.035
kW
-
-
kWh
10323
12903
GJ
37
46
dB
55
55
mg/kWh
20
16
See
The back cover for contact details.
18
24
28
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
18
24
28
18.0
24.0
28.0
6.0
8.0
9.4
93
93
93
88.0
87.9
87.9
98.1
98.0
98.0
0.040
0.045
0.050
0.014
0.014
0.014
0.003
0.003
0.003
0.035
0.035
0.040
-
-
-
15484
20645
24086
56
74
87
56
53
56
16
24
22
7219708 - 01 (04/15)
32
Yes
No
No
No
No
32
32.0
10.7
93
87.9
98.0
0.050
0.014
0.003
0.045
-
27527
99
59
24

Hide quick links: