Setting Up The Storage Unit To Attach To An Hp Alphaserver Openvms Host System With Fibre-Channel Adapters; Adding Or Modifying Alphaserver Fibre-Channel Connections For The Openvms Host; Defining Openvms Fibre-Channel Adapters To The Storage Unit; Example Results Of The Wwidmgr Command - IBM TotalStorage DS6000 Attachment Manual

Host systems attachment guide
Hide thumbs Also See for TotalStorage DS6000:
Table of Contents

Advertisement

2. Place the AlphaServer into console mode.
3. Type wwidmgr -show adapter to check the mode. Figure 26 shows example
Figure 26. Example results of the wwidmgr command.
4. Type wwidmgr -set adapter -item 9999 -topo fabric to set the KGPSA host
5. Type init to initialize the system.
6. Type wwidmgr -show adapter to check the mode.
Setting up the storage unit to attach to an HP AlphaServer OpenVMS
host system with fibre-channel adapters
This section describes setting up the storage unit to attach to an HP AlphaServer
OpenVMS host system with fibre-channel adapters.
Adding or modifying AlphaServer fibre-channel connections for the
OpenVMS host
To create, remove, or modify the AlphaServer connections, use the IBM
TotalStorage DS Storage Manager. When you create a connection, it is necessary
to specify the worldwide port name of the host connection. See "Locating the
worldwide port name (WWPN)," on page 211 for procedures on how to locate the
WWPN.

Defining OpenVMS fibre-channel adapters to the storage unit

This section lists the steps you must perform to define OpenVMS fibre-channel
adapters to the storage unit.
You must create a storage complex before defining each host adapter to the
storage unit. Use the IBM TotalStorage DS Storage Manager to create a storage
complex. You can use the following menu path: click Real-time manager, click
Manage hardware, click Storage complexes.
To define each host adapter to the storage unit, perform the following steps using
the IBM TotalStorage DS Storage Manager.
Note: These instructions assume that you are familiar with the IBM TotalStorage
1. Logon to the IBM TotalStorage DS Storage Manager and click Real-time
2. From the Select action box, click Create, then click Go.
3. From the General host information screen, complete the following fields for
output from the wwidmgr command.
item
adapter
WWN
[ 0]
pga0.0.4.1
2000-0000-C923-1765
adapter mode to FABRIC.
DS Storage Manager.
manager, click Manage hardware, click Host systems.
each fibre-channel host adapter. When finished, click OK.
v Host type
v Nickname
Chapter 5. Attaching to a Hewlett-Packard AlphaServer OpenVMS host
Cur. Topo
Next Topo
FABRIC
FABRIC