Figure 71. Example results for the switchshow command

Displaying zoning information for the switch

This section describes the command needed to display zoning information for the
switch.
Use the cfgShow command to display the zoning information of the switch.
Figure 72 on page 153 shows a zoning example based on the unique worldwide
port names of the host adapters and the storage unit fibre-channel ports. This is
known as soft zoning. Each path to a storage unit LUN has a separate zone. For
information on locating the worldwide port name for an SGI host, see "Locating the
WWPN for an SGI host" on page 215.
152
DS6000 Host Systems Attachment Guide
snj2109s16h1:osl> switchshow
switchName:
snj2109s16h1
switchType:
2.4
switchState:
Online
switchRole:
Principal
switchDomain:
1
switchId:
fffc01
switchWwn:
10:00:00:60:69:12:30:25
switchBeacon:
OFF
port 0: sw Online
port 1: sw Online
port 2: sw Online
port 3: sw Online
port 4: sw Online
port 5: sw Online
port 6: sw Online
port 7: sw Online
port 8: sw Online
port 9: sw Online
port 10: sw Online
port 11: sw Online
port 12: sw Online
port 13: sw Online
port 14: sw Online
port 15: sw Online
F-Port 21:00:00:e0:8b:04:d5:39
F-Port 21:00:00:e0:8b:04:ee:3a
F-Port 21:00:00:e0:8b:03:8f:e6
F-Port 21:00:00:e0:8b:04:13:3a
F-Port 21:00:00:e0:8b:05:c4:07
F-Port 21:00:00:e0:8b:05:0f:08
F-Port 21:00:00:e0:8b:05:d2:07
F-Port 21:00:00:e0:8b:05:08:08
F-Port 21:00:00:e0:8b:04:e9:39
L-Port 1 public
F-Port 21:00:00:e0:8b:03:97:e6
L-Port 1 public
F-Port 21:00:00:e0:8b:05:d5:07
F-Port 50:05:07:63:00:c3:91:74
F-Port 21:00:00:e0:8b:05:07:08
F-Port 50:05:07:63:00:c7:91:74