HP Pro Tablet 608 G1 Maintenance And Service Manual page 24

Hide thumbs Also See for Pro Tablet 608 G1:
Table of Contents

Advertisement

1.
Remove the 1.2 mm P0 Phillips-head screw (1) that secures the battery connector bracket to the system
board.
2.
Lift the battery connector (2) to remove it from the system board.
3.
Carefully remove the battery ribbon cable (3) from the adhesive that secures it to the system board, and
then disconnect the battery from the system board.
Reverse this procedure to connect the battery.
18
Chapter 5 Removal and replacement procedures

Hide quick links: