Page 6
SB-2-658-D
1.
Remove Adjusting Knob (7),
Spring (8), and Needle (9).
4.
Remove Valve (11).
7.
Push out the Front Airvalve
Seal with a finger.
10. Fit new Seal to gunbody and
press firmly to ensure Seal is
engaged.
2.
Loosen Housing (10).
5.
Using Service Tool SPN-7,
engage groove behind the
Valve Seat.
8.
Turn the Gun upside down
and let the Seal fall out.
11. Fit
New
Valve
Seat
Service Tool so that the
groove faces the handle end
of tool.
3.
Remove Housing (10) and
Airvalve Spring.
6.
Remove Valve Seat.
9.
Fit New Front Seal to Service
Tool so that the groove faces
the handle end of tool.
to