– PPMs ("Removing a PPM" on page 29), except the PPM installed in slot
1
– DIMMS ("Removing DIMMs" on page 76), except the first bank from
one memory board
– Hard drives ("Removing a hot-plug SCSI hard drive" on page 50)
– Peripheral devices
2. Install each remaining system component, rebooting between each
installation to isolate any failed components.
3. Clear the system NVRAM ("System maintenance switch" on page 103).
4. Replace the system board.
IMPORTANT: If replacing the system board or clearing NVRAM,
you must re-enter the server serial number through RBSU ("Re-entering
the server serial number and product ID" on page 41).