Connect Third Party Controls:
Use conduit or NM type cable as appropriate. (Note: acceptable wire is
both solid core and stranded. Gauge range is 16-24 AWG.)
Open appropriate terminals by depressing appropriate terminal buttons.
Make connections to the appropriate ports. (Note: wire strip length is
9-10mm/.35-.39 inches.)
Refer to applicable protocol wiring diagrams.
Verify Successful Installation:
•
Apply power to circuit.
•
Green "Power" LED will illuminate indicating successful installation
and product functionality.
•
Optional: If data is present at any control port, appropriate LED will
indicate status.
•
Disconnect power and install cover.
•
Restore power and configure device using Ketra Design Studio
Software.
•
For software download and updates, visit software.goketra.com.