  • Page 1 Installation Guide Models D3-FXSQ D3-FXRD D3-ADSQ D3-ADRD D3-WWSQ D3-WWRD...
  • Page 2 Due to the risk of electric shock, a licensed electrician should install this power supply unit in strict compliance with the National Electrical Code and any state or local code which may apply. P/N 040444 Rev E 2 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 3: Table Of Contents

    Part 3: Installing Drywall Part 4: Apply Spackle Flange Trim Retainer (Mud-In Only) Part 5: Apply Joint Compound Part 6: Apply Trim Additional Operations Troubleshooting Warranty & Tech Support P/N 040444 Rev E 3 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 4: Product Overview

    Product Overview Ketra’s D3 family includes fixed, adjustable, and wall-wash downlights. Every model features a low-profile housing, wireless communication, and field-replaceable optics and electronics. With a wealth of trim and optic accessories, the D3 is ideal for a large variety of applications. It uses a fully-tunable spectrum capable of delivering high- quality white, saturated, and pastel light.
  • Page 5: Included Components/Supported Models

    D3-WWSQ For instructions on setting default states in Design Studio, see the Design Studio Manual available on our website. The manual has sections dedicated to emergency mode and setting default states for Ketra lights P/N 040444 Rev E 5 | D3 INSTALLATION GUIDE...
  • Page 6: Specifications

    KetraNet Mesh * Ketra lighting products should not be connected to, or directly controlled by, AC mains line voltage dimmers. These types of dimmers may also be referred to as phase cut, triac, forward-phase, reverse-phase, ELV, or MLV dimmers. Ketra's lighting products should only be controlled via our digital control architecture.
  • Page 7: Installation

    Allow horizontal movement • Allows horizontal or vertical movement post-mounting post-mounting • Ideal with wooden studs or • Ideal for commercial settings t-grid ceilings continued on next page P/N 040444 Rev E 7 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 8 Screw the ends of both bars into the wooden joists, fixing the housing in place. (see fig. 3) T- Grid ceiling only: Bend the tabs on the nailer bars to lock them to the t-grid. (see fig. 4) fig. 4 P/N 040444 Rev E 8 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 9 Tilt and rotate the emitter chassis to open an unobstructed path to the butterfly bracket openings Rotation Lock and Release on either side of the housing. Unlocked Locked Unlocked fig. 5 fig. 6 continued on next page P/N 040444 Rev E 9 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 10 Note: The opening in the c-shaped kick reflector should face the wall. Reinsert the cardboard plug to protect the optic from dust during the rest of the installation. continued on next page P/N 040444 Rev E 10 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 11 Loosen the collar’s two outer screws, freeing the collar for rotation. Realign the collar using its v-shaped notches and an alignment string or laser. Re-tighten the screws to lock the collar’s new position. P/N 040444 Rev E 11 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 12: Part 2: Wire The Fixture

    After verifying a successful installation, remove power and continue to Part Three. * Ketra lighting products should not be connected to, or directly controlled by, AC mains line voltage dimmers. These types of dimmers may also be referred to as phase cut, triac, forward-phase, reverse-phase, ELV, or MLV dimmers. Ketra's lighting products should only be controlled via our digital control architecture.
  • Page 13: Part 3: Installing Drywall

    1.125 in (28.575 mm), use the blue coded short set; for ceiling thickness in range 0.875 in (225.425 mm) to 1.5 in (38.1 mm), use the red coded long set. Note: The retainer assembly should be flush with the drywall. fig. 9 P/N 040444 Rev E 13 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 14: Part 5: Apply Joint Compound

    Mud-in and flanged downlights have different processes for applying their trims. Please read only the appropriate section below. Applying trim to mud-in downlight Press the flangeless trim into the trim retainer (see fig. 11). fig. 11 continued on next page P/N 040444 Rev E 14 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 15 1) CIRCLED DIMENSIONS ARE CRITICAL AND SUBJECT TO INSPECTION 2) MATERIAL: 3) FINISH: 4) COLOR: 5) ANY DEVIATIONS OR SUBSTITUTIONS MUST FIRST BE APPROVED BY A KETRA ENGINEER 6) PARTS TO BE CLEAN AND FREE FROM MACHINE OIL, REMOVE ALL BURRS AND BREAK SHARP EDGES DATE DRAWN BY...
  • Page 16: Additional Operations

    To set optic at the low regress position pull optic directly down. Light engine will magnetically lock into place (see fig. 17). Emitter Regress Depth Adjust To Raise: Push To Lower: Pull fig. 16 fig. 17 P/N 040444 Rev E 16 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 17 Luminaire Disconnect Disconnect Emitter Module Tilt locked at 40˚ . Emitter Module in Full Regress Unlocked and rotated so that Emitter Module tilts away from Power Supply P/N 040444 Rev E 17 | D3 INSTALLATION GUIDE © 2019 Ketra, Inc. All rights reserved...
  • Page 18: Troubleshooting

    D3 and other Ketra devices. Note: Magenta can indicate success or failure. It indicates success if there are no other powered- on Ketra devices within 50 ft (15.24 mm); otherwise, it indicates a problem. P/N 040444 Rev E 18 | D3 INSTALLATION GUIDE...