FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
WARNING:
If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life. Installation and service
must be performed by a qualified installer,
service agency or the gas supplier.
O- T L
Tested &
Portland
Listed By
Oregon USA
C
US
OMNI-Test Laboratories, Inc,
Report # 268-S-22-5
Report # 268-S-06b-2
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
E33GI
Glass Burner & Proflame IPI Valve
OWNER'S MANUAL
kit is used.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must not be longer than 36in.,
a shut off valve must be installed; only direct vent sealed combustion products are
approved for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms
containing gas fired direct vent appliances. The fireplace damper must be removed or
welded in the open position prior to installation of a fireplace insert.
Gas Insert -
Leave this manual with the appliance.
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
INSTALLER:
CONSUMER:
50-2578

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E33GI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro E33GI

  • Page 1 E33GI Gas Insert - Glass Burner & Proflame IPI Valve OWNER’S MANUAL INSTALLER: FOR YOUR SAFETY Leave this manual with the appliance. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any CONSUMER: other appliance.
  • Page 2: Safety Precautions

    Do not abuse the glass by striking it or slamming the door shut. HOT GLASS WILL • If the E33GI unit is pulled out of its installation, and CAUSE BURNS the vent-air intake system is disconnected for any reason, ensure that the vent-air intake pipes are reconnected and...
  • Page 3: Table Of Contents

    Table of Contents Safety Precautions......................2 Table of Contents......................3 Codes And Approvals.......................4 Specifications........................5 Rating Label Location...................5 Dimensions......................5 E33GI Options Dimensions..................6 Operating Instructions.....................7 Lighting and Turning Off Instructions..............7 Venturi Adjustment....................8 Normal Sounds During Operation.................8 Remote Control Operations...................9 Wall Mounting the Receiver.................11 Initializing the System for the First Time..............11 Maintenance And Service....................14...
  • Page 4: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “D ”...
  • Page 5: Specifications

    The rating label is located on the left side of the unit, next to the receiver box. imensions 22.16 9.09 9.06 14.05 11.24 33.00 28.89 27.05 21.55 19.78 16.64 18.55 18.00 FRONT LEFT RIGHT 17.40 Figure 1: E33GI Exterior Dimensions.
  • Page 6: E33Gi Options Dimensions

    Specifications 8 " " 4 " 2 " Figure 2: E33GI Contemporary Surround with Base Shelf and Riser. Table 1: E33GI Options Dimensions. Regular Surround Contemporary Surround Extruded Surround Height 26.5” (673 mm) 26.5” (673 mm) 26.5” (673 mm) Width ”...
  • Page 7: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:...
  • Page 8: Venturi Adjustment

    Operating Instructions entuRi Djustment The venturi adjustment lever is located on the right side of the unit, behind the surround panel (see Figure 4). To avoid touching hot surfaces under the unit, use the Door Tool to adjust the venturi. The venturi allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements.
  • Page 9: Remote Control Operations

    The Proflame GTMF is a modular remote control system that directs the functions of the E33GI. The Proflame GTMF is configured to control the on/off main burner operation, its flame levels and provides on/ off and Smart thermostatic control of the appliance. The system controls a remotely actuated 120V/60Hz power outlet, fan speed through six (6) levels and has a constantly powered 120V/60Hz power outlet.
  • Page 10 Operating Instructions TRANSMITTER (Remote Control with LCD Display) The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Figure 5). The Transmitter is powered by three (3) AAA type batteries. A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on/off or index through Thermostat functions (Figure 5 &...
  • Page 11: Wall Mounting The Receiver

    Operating Instructions emote ounting eceiVeR ptionaL The receiver can be removed from the unit and placed inside a standard Junction type wall box or another convenient location. This installation can take place up to 6’ft (1.8 m) from the appliance control valve. 1.
  • Page 12 Operating Instructions Turn off the Appliance Room Temperature Press the ON/OFF Key on the Transmitter. The Transmitter LCD display will only show the room temperature and Icon (see Figure 11). A single “beep” from the Receiver confirms reception of the command and both the pilot light (if the unit is not set to continuous pilot) and main burner will turn off.
  • Page 13 Operating Instructions Key lock This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP keys at the same time and the a lock will appear (see Figure 15). To de-activate this function, press the MODE and UP Keys at the same time.
  • Page 14: Maintenance And Service

    The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 15). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
  • Page 15: Glass Door Removal

    Maintenance And Service Lass emoVaL Figure 18: Door Release. Figure 19: Door Removal. Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 18) and pulling the latch out then up. When the two (2) latches have been released, tilt the bottom of the door forward and then lift up to unhook the top door tabs (see Figure 19).
  • Page 16: Removing Valve Cover

    Maintenance And Service emoVing aLVe oVeR The valve cover can be removed to access the gas valve. 1. Use a T-20 screwdriver to remove the eight screws that hold down the valve cover shown in Fig. 20. VALVE COVER Figure 20: Valve Cover.
  • Page 17: Fuel Conversion

    Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 18 Fuel Conversion 10. Reinstall the burner, porcelain panels, bowl, glass material, and glass door. Also refer to s econDary & b in your Owner’s Manual. When re- nstallatIon Irebox Iner urner emoVal nstallatIon installing the burner, ensure that the burner to pilot hood relationship is similar to what is shown in Figure 21.
  • Page 19: Initial Installation

    The vent length for the E33GI must be between 8ft (2.44 m) and 30ft (9.14 m). This model is vented with a 3” intake and a 3” exhaust aluminum or stainless steel approved flex vent leading into a vertical termination cap.
  • Page 20: Venting Fireplace Inserts

    Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed. NOTE: If the E33GI unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and reconnected with three (3) sheet metal screws evenly spaced.
  • Page 21 (either silicone or stove cement). The flue damper can be fully blocked open or removed for installation of the E33GI; the smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. The fireplace and fireplace chimney must be clean, in good working order and constructed of non-combustible materials.
  • Page 22: Direct Vent Vertical Vent Termination

    1. Plan your installation and clearances to combustibles. The E33GI may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Also refer to the I...
  • Page 23: Installing The Unit

    4. Check that the chimney clean outs fit properly. The flue damper must be fully blocked open or removed for installation of the E33GI; the smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
  • Page 24: Zero Clearance Fireplace Installation

    Initial Installation QUALIFIED INSTALLERS ONLY (zc) f LeaRance iRepLace nstaLLation The metal floor of the ZC solid fuel firebox can be removed to allow the installation of the insert. THE CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS 4” (102 mm). YOU MUST USE THE LEVELING LEGS TO RAISE THE INSERT A MINIMUM OF 4”...
  • Page 25 Initial Installation QUALIFIED INSTALLERS ONLY Figure 30: Wiring Schematic.
  • Page 26 ½ psi (3.5 kPa). Figure 32: Gas Valve with Cover Removed. Table 5: Orifice and Pressure Information. E33GI With Log Set & Proflame Valve Main Burner Natural Gas Propane Gas Orifice:...
  • Page 27 Initial Installation QUALIFIED INSTALLERS ONLY TO TEST VALVE PRESSURES (INPUT RATES): The pressure taps are located on the front side of the valve (see Figure 33). 1. Using a long flat bladed screwdriver, turn set screw counter-clockwise to loosen. 2. Place in (8 mm) I.D.
  • Page 28: Adjusting The Pilot Flame

    Initial Installation QUALIFIED INSTALLERS ONLY Djusting iLot Lame The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted. The pilot flame should envelope ⅜” to ½” (10 to 13mm) of the thermocouple (see Figure 34). However, should the need arise, follow Steps 1- 2 below.
  • Page 29: Secondary Installation

    Additional Base Shelf Risers can be fastened together to increase the height in increments of 2⅛” (54 mm). This Base Shelf may be used in conjunction with the any of the E33GI surround panel options, and it may also be used with the E33GI Trimmable Surround. The Base Shelf and Riser are sold separately.
  • Page 30: Optional Trimmable Panel

    Modifying the Surround Panel: The E33GI Trimmable Surround Panels are large rectangular panels that may be cut for use in cases that a non-standard fireplace opening (e.g. an arched opening) is to be filled. Optionally this surround can be left uncut and placed in front of the fireplace opening.
  • Page 31: Surround Panel Installation

    Every surround panel comes with a burner switch and wires already installed. Because the E33GI is completely remote controlled, there is no need for a burner switch. A blank filler switch is included in the E33GI manual bag and can be installed in the panel in place of the burner switch/wires.
  • Page 32: Firebox Liner And Burner Tray Removal / Installation

    WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 1. Ensure the E33GI is turned off and allow the unit to cool. 2. Remove the glass door as shown in the m...
  • Page 33: Installing The Glass Beads

    Secondary Installation nstaLLing the Lass eaDs Pour the glass beads into the bowl and evenly distribute over the entire bowl. Ensure that the pilot hole remains clear of any glass. Burner bowl with glass installed. Figure 44:...
  • Page 34: Troubleshooting

    TroubleShooting iagnostic Lash oDes 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset. 2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 3.
  • Page 35: Troubleshooting

    TroubleShooting Problem Possible Cause Solution The pilot flame has gone out Thermostat · Turn it ON does not The On/Off switch is turn to OFF work The thermostat is set too high · Set the thermostat to a lower temperature ·...
  • Page 36 TroubleShooting Problem Possible Cause Solution · Turn the system off by pressing the ON/OFF button on the transmitter · After approximately 2 seconds press the ON/OFF button on the transmitter again. · In the manual flame control mode, use the down arrow button to reduce the flame to off, indicated by the word OFF displayed on the transmitter LCD screen.
  • Page 37: Parts List

    50-2565 Pilot Gasket EC-021 Porcelain Liner Set 50-2437 E33GI Owner’s Manual 50-2578 E33GI Conversion Kit NG to LP 50-2489 E33GI Conversion Kit LP to NG 50-2539 Blank Filler Switch EG30-010 12 oz. Can of Metallic Black Touch Up Paint PAINT-12-MB...
  • Page 38 Parts List Reference Option Description Part Number Number Regular Surround Panel 50-2428 Contemporary Surround Panel 50-2429 Extruded Surround Panel 50-2430 Trimmable Surround Panel 50-2432 Base Shelf 50-2434 Base Shelf Riser 50-2435 Safety Screen 50-2496...
  • Page 39: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 40: Parts Diagram - Options

    Parts Diagram - Options...
  • Page 41: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ƒ...
  • Page 42: Installation Data Sheet

    � NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in WC PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com April 30, 2013 C-12586...