Lamp Replacement - Sanyo PLC-EF10E Service Manual

Hide thumbs Also See for PLC-EF10E:
Table of Contents

Advertisement

Lamp Replacement

WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can
become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can shatter and cause injury.
Procedure
1. Turn off the projector and allow the projector to cool thoroughly.
2. Disconnect the AC cord from the projector.
3. Loose a screw with a screwdriver and remove the lamp cover.
4. Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
5. Replace the lamp assembly securely and tighten 2 screws.
6. Place the lamp cover and tighten a screw.
7. Connect the AC cord to the projector.
8. Reset the lamp replacement monitor timer, see below explanation.
Note:
- Do not reset the LAMP REPLACEMENT MONITOR TIMER, except
after the lamp is replaced.
- The projector can not be turned-on with the lamp cover removed,
because when the lamp cover is removed, the interlock switch is also
released to switch off the mains power for safety.
How to reset the lamp replacement monitor
timer
1. Turn the projector on. Press the "MENU" button on the
projector and display menu bar. Select setting menu and
select "Lamp age" on the setting menu of menu bar.
2. "Lamp replace monitor Reset?" is displayed for confirma-
tion.Select "Yes" to reset the lamp replace timer.
Please refer to the owners manual for further information.
Recommendation
Should the air filter become clogged with dust particles, it
will reduce the cooling fan's effectiveness and may result in
internal heat build up and short lamp life. We recommend
cleaning the air filter after the projection lamp is replaced.
Refer to "Air Filter Cleaning".
How to check the lamp illumination time
The LAMP REPLACE indicator will illuminate and the
LAMP REPLACE warning message will appear on the
screen when the total illumination time of lamp reach-
es to 600 hours. These are to indicate that lamp
replacement is necessary.
You can check the remaining time by following proce-
dure.
1. Press and hold the pointer
20 seconds. The service mode window will be dis-
played on the screen as shown below.
2. You can see the remaining time to "600 hours".
For example: "0567" means 567 hours remaining.
3. Press the POWER ON-OFF button to quit the ser-
button for more than
-20-
Part No.: 610 270 6796
Lamp cover
Lamp Assembly
vice mode.
Data No.
Service
037
Mode
Remaining Time (hours)
Data
0567

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-ef10elPlc-ef10b

Table of Contents