Electrical Adjustments
COMMON CENTRE ADJUSTMENT
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
[RED COMMON CENTRE ADJUSTMENT]
3. Cover the G and B panel to cut the light transit.
4. Select Data no. "020" and change data value (Refer to
"IIC data adjustment ") to obtain the minimum flicker
on picture.
[GREEN COMMON CENTRE ADJUSTMENT]
3. Cover the R and B panel to cut the light transit.
4. Select Data no. "021" and change data value (Refer to
"IIC data adjustment ") to obtain the minimum flicker
on picture.
[BLUE COMMON CENTRE ADJUSTMENT]
3. Cover the G and R panel to cut the light transit.
4. Select Data no. "022" and change data value (Refer to
"IIC data adjustment ") to obtain the minimum flicker
on picture.
WHITE BALANCE ADJUSTMENT-[CG]
[CG WHITE BALANCE]
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Select Data no. "014" (Red) and "016" (Blue), and
change data values (Refer to "IIC data adjustment ")
respectively to make a proper white balance.
Confirm the withe balance in AV and COMPUTER
mode.
WHITE BALANCE ADJUSTMENT-[AV]
[AV WHITE BALANCE]
1. Receive the 16-step gray scale video signal.
2. Set to AV mode.
3. Select Data no. "01A" (Red) and "01C" (Blue), and
change data values (Refer to "IIC data adjustment ")
respectively to make a proper white balance.
Confirm the withe balance in AV and COMPUTER
mode.