Electrical Adjustments
OFFSET ADJUSTMENT
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
[RED OFFSET ADJUSTMENT]
3. Cover the G and B panel to cut the light transit.
4. Select Data no. "023" and change data value (Refer to
"IIC data adjustment ") to disappear the vertical
stripes on the screen.
[GREEN COMMON CENTRE ADJUSTMENT]
5. Cover the R and B panel to cut the light transit.
6. Select Data no. "024" and change data value (Refer to
"IIC data adjustment ") to disappear the vertical
stripes on the screen.
[BLUE COMMON CENTRE ADJUSTMENT]
7. Cover the G and R panel to cut the light transit.
8. Select Data no. "025" and change data value (Refer to
"IIC data adjustment ") to disappear the vertical
stripes on the screen.
Project all lights and conform that the no vertical stripes
are observed on the screen.