Adjustment
12

Target positioning sensor

.05.10
● Adjust sensor 1 (screws 2 ) in accordance with the requirement .
12 - 12
Requirement
There should be a clearance of 0.2 – 0.3 mm between sensor 1 and control cam 3 .
Fig. 12 - 11
1
2
3