Mounting/Connecting The Start Inhibitor (Only On Machines With Quick-Flange Motor); Error Messages - Pfaff 918 U Instruction Manual

Hide thumbs Also See for 918 U:
Table of Contents

Advertisement

Installation and commissioning
8
Mounting/connecting the start inhibitor
.08
● For machines delivered without a table, the plate 1 from the accessories should be
● Loosen screws 3 and adjust switch 4 so that the switch lug 2 is free when the sewing
● Connect plugs 5 and 6 to the switch 4 .
Function check of the start inhibitor
● Switch the machine on at the main switch and tilt it back.
● If the message does not appear, check the setting of switch 4 .
● Set the sewing head upright and acknowledge the error message by pressing the TE/
8 - 8
92-015
3
Fig. 8 - 09
mounted under the table top, so that the switch lug 2 is resting on plate 1 when the
sewing head is in an upright position.
head is tilted back and pressed when the sewing head is upright.
The error message "E9" must appear on the control panel.
Speed key. The machine is ready for operation again.
1
6
ERROR
E
9
(only on machines with Quick-flange motor)
2
5
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

938 u

Table of Contents