40. Changing the buttonhole sensor
Note:
The buttonhole sensor must be replaced as a complete unit.
Removal:
•
Disconnect the machine lead cord.
•
Remove the needle and the presser foot.
•
Remove the detachable work support.
•
Remove the housing covers as described in this manual.
•
Remove the connecting plug 15 from button hole sensor (fig. 74).
•
Remove Seeger circlip ring 153 (fig. 100).
•
Remove lowering lever 154.
•
Cut off cable clip 155 with a knife (fig. 101).
•
Remove buttonhole sensor 156 complete with spring (fig. 100).
Refitting:
•
Install buttonhole sensor 156 complete with spring.
•
Place the flat cable into the housing of the machine.
•
Insert cable clip 155 from the top and pull it together fig. 101).
•
Cut off the protruding end of cable clip 155.
•
Fit lowering lever 154 (fig. 100).
•
Mount Seeger circlip ring 153 and seal lowering lever.
•
Mount connection plug 15 onto the circuit board (fig. 74).
•
Refit the housing covers as described in this manual.
•
Carry out a function check.
94