Target Positioning Sensor (Only On The 918U And 938U) - Pfaff 918 Adjustment Manual

Hide thumbs Also See for 918:
Table of Contents

Advertisement

Adjustment
1
Target positioning sensor
.05.12
● Adjust sensor 1 (screws 2) in accordance with the requirement.
18
Requirement
There should be a clearance of 0.2 – 0.3 mm between sensor 1 and control cam 3.
Fig. 1 - 12
(only on the 918U and 938U)
1
3
2

Advertisement