Justierung
1
Target positioning sensor
.05.12
● Adjust sensor 1 (screws 2) in accordance with the requirement.
18
Requirement
There should be a clearance of 0.2 – 0.3 mm between sensor 1 and control cam 3.
Fig. 1 - 13
(only on the 939U)
1
3
2