TECHNICAL DETAILS/REGULATIONS

National installation regulations:
• Gas safety installation and use regulations 1984 plus all relevant
safety and building regulations concerning fi re installation
• Document J: Combustion appliances and fuel storage systems
Model
Country
Product identifi cation no
Type of appliance under CE-norm
Category of appliance
Nominal heat input
(Gross calorifi c value)
Nominal heat output
Effi ciency class
NOx-class
Gas rate (max.)
Supply pressure
Burner pressure (max.) Hot
Burner pressure (max.) Cold
Burner pressure (min.)
Primary air inlet burner
Required minimal
ventilation opening(***)
Gas regulator block (remote control)
Main burner
Main burner injector
Pilot light burner - Oxy-stop
Gas connection
Flue connection: Lined
Unlined (UK only)
Installation instructions
: UNICA-2 70
: GB; Great Britain/IE; Ireland
: 0063BQ3938
: B
11AS
: I
natural gas G20
2H
: 6.95 kW
: 5.60 kW
: 2 (80%)
: 5
3
: 0.65 m
/hr.
s
: 20.0 mbar
: 11.8 mbar(*)
: 11.0 mbar(**)
: 1.6 mbar
: Ø12 mm
: 100 cm
2
: Mertik GV 60
: 500 x 100 mm
: no 560
(= 7x Ø0.90 mm)
: SIT 9040
: 3/8" G / Ø8 mm
: Ø100 mm - Ø106 mm (4")
: Ø180 mm (7")
Appliance: 252 x 34 mm
English
: GB; Great Britain/IE; Ireland
: 0063BQ3938
: B
11AS
: I
butane/propane G30/G31
3B/P
: Butane (G30) : 7.6 kW
Propane (G31) : 7.1 kW
: 5,7 - 6,5 kW
: 2 (80%)
: 5
: Butane (G30) : 590 gr/hr.
Propane (G31) : 530 gr/hr.
: Butane (G30) : 30.0 mbar
Propane (G31) : 37.0 mbar
: Butane (G30) : 29.1 mbar
Propane (G31) : 34.6 mbar
: Butane (G30) : 29.1 mbar
Propane (G31) : 34.6 mbar
: 5.0 mbar
: 15x 20 mm + 20x 25 mm
: 100 cm
2
: Mertik GV 60
: 500 x 100 mm
: no 220
(= 7x Ø0.56 mm)
: SIT 9226
: 3/8" G / Ø8 mm
: Ø100 mm - Ø106 mm (4")
: Ø180 mm (7")