2.1
POSITIONING THE APPLIANCE
Important:
Read one of the following instructions for fi tting the appliance, as applicable:
Paragraph 2.1.1
Paragraph 2.1.2
Paragraph 2.1.3
Installation instructions
Never use combustible materials during the installation. The
appliance may not be installed against a fl ammable rear wall.
During installation of the gas fi re, a clearance of 3 mm should
be maintained on all sides of the appliance to allow for
expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides
may be fi tted with a strip of white, loose insulation wool
(heat-resistant to 1000°C), width 15 cm max. to protect
the wall.
Do not use fi breglass or Rockwool, or any other sort of
insulating material. These emit a pungent odour.
This is considered extremely unpleasant. They may
also cause discolouring of the chimney.
Flammable materials, such as curtains, should not be
placed in the vicinity of the gas fi re.
Minimum safe distance: 100 cm.
Position the appliance at least 12 cm above the fl oor height.
Not required with a non combustible fl oor.
Ensure that the temperature of the fl oor under and in front
of the appliance can never rise above 85°C!
Make use of a temperature protection plate (of nonfl ammable
material) on the fl oor if necessary.
Take care with a fl oor made of a fl ammable material.
Minimum distance between the appliance and a front wooden
fi replace; with a depth of less than 10 cm, is:
* 5 cm on the sides: (min. distance: side appliance - leg
* 40 cm at the top: (min. distance: top appliance - bottom
The temperature on the underside of the beam of the wooden
fi replace must never exceed 85°C. Optional: insulate the
bottom of the wooden beam with a fi reproof plate.
Fitting into a new chimney
Fitting into an existing opening larger than the appliance
Fitting into an existing opening equal or smaller than the appliance
wooden fi replace surround)
of beam wooden fi replace surround)