CO-250 Offl ine Lock User Guide
After the lock has been programmed, present credentials to operate the lock as follows:
Credential Type
Present credential to reader 
Credential
Present credential
+ PIN Credential
to reader 
1 If the PIN is entered incorrectly, press "
2 The "#" key is used as ENTER key for PINs with fewer than the minimum number of digits. Default minimum digits
is six (6). This can be confi gured with the HHD, so users do not have to push the "#" key.
If you encounter problems while performing any of the following tests, review the installation guide
and correct any problems.

Mechanical Testing

1. Rotate the inside lever or depress the push bar to open the door. Operation should be smooth,
and the latch should retract.
2. Insert the key into the keyway and rotate the key and the outside lever to open the door.
Operation should be smooth, and the latch should retract.

Electronic Testing

1. For locks with a keypad, press any number key. The lock will beep. Use the default PIN (13579
and "#") to verify access in construction mode.
2. Present a user credential to the reader. The lock will beep, the Schlage button will light green and
the lock will unlock. (If this is the fi rst credential presented to a new lock, it becomes the master
construction programming credential. See Construction Access Mode on page 5.)
During normal use after adding user credentials, the lock will beep and the Schlage button will light
green when a valid credential is presented. The Schlage button will blink red twice when the credential
is not valid for the lock.

RESETTING TO FACTORY DEFAULTS

!
All information in the lock will be deleted and reset to factory defaults!
The door must be locked (not toggled open or in the middle of normal access) before resetting to
factory defaults.
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the
Schlage button, indicating confi rmation.
2. After confi rmation signals, release the Schlage button.
3. Rotate the mechanical key within 10 seconds and hold. Continue holding the key until
confi rmation signals are observed.
4. The Schlage button will light green for one second and a one-second beep will sound to confi rm
reset to factory defaults.
If the mechanical key is not rotated within 10 seconds, two beeps and two red blinks indicate
timeout.

USING THE LOCK

1
Press PIN
" to start over.
*

TESTING

6
Action
Green blink and access granted
Within 5 seconds,
2
Press #
Green blink and
access granted