The 5100 series lock is a stand-alone, microprocessor controlled, electromechani-
cal locking system. The 5100 employs a heavy-duty mechanical design with fewer
moving parts than a standard cylindrical lockset, for ease of installation and high
reliability. It is powered by four, standard AA batteries, providing up to 80,000 acti-
vations.
Operationally, the outside lever is normally locked and the inside lever is always
free to allow egress. Electronic access control is achieved by entering an "Access
Credential" (magnetic stripe card, code, iButton Key, or Prox fob or card).
Electronic access control capabilities are listed below by model. All models are
designed to accommodate an emergency mechanical key override. Standard fea-
tures of the CM models include up to 1000 user memory, real time features includ-
ing time zones and holidays, and audit trail of up to 1000 events. Optional ATK
(audit trail - key override) will note any use of the mechanical key on the audit trail
report. Manual and computer programming is supported by all models. The PRO
models are manually programmed to accept up to 100 codes.
Functions:
5190: Office Function - has "Lock" and "Unlock" buttons on inside escutcheon -
function not available on PRO
5196: Storeroom/Classroom Function - can be unlocked by "toggle" credential and
relocked again by same. See programming guide for more information.
5198: Classroom Function with inside iButton reader - can be toggled unlocked by
iButton plus pin (code). Can be relocked immediately from inside iButton reader in
an emergency.
Models:
KPI:
iButton reader and keypad
IBO:
iButton reader only
MGK: Magnetic stripe card reader, iButton reader and keypad
MGI:
Magnetic stripe card reader and iButton reader
PXK:
HID Prox card reader, iButton reader, and keypad
PXI:
HID Prox card reader and iButton reader
PPK:
interflex ProxIF Prox card reader, iButton reader, and keypad
PPI:
interflex ProxIF Prox card reader and iButton reader
PCK:
Casi Rusco Prox card reader, iButton reader, and keypad
PCI:
Casi Rusco Prox card reader and iButton reader
PRO:
Keypad only - no computer programming, 100 code memory
Options:
ATK:
Audit trail of mechanical key use (not available on PRO)
HSS:
High security screws on inside escutcheon
SLB:
2-3/4" backset, 1/2" latch bolt
OLB:
2-3/8" backset, 1/2" latch bolt
ELB:
2-3/4" backset, 3/4" latch bolt
T3:
Track 3 card reader (data on track 3
must be ABA track 2 format) - MGI/MGK only
KD:
Keyed Different, includes Schlage
Everest cylinder
LC:
Less Cylinder
Form 51005 Rev. D
CM5100 COMPUTER MANAGED CYLINDRICAL LOCK
5100 CYLINDRICAL
LOCKSET - STANDARD
INSTALLATION MANUAL
CM5100-KPI
CM5100-IBO
CM5100-MGK
CM5100-MGI
CM5100-PXK
CM5100-PXI
CM5100-PPK
CM5100-PPI
CM5100-PCK
CM5100-PCI
PRO5100
CM5198
SAFE SCHOOL LOCK
WITH iBUTTON
READER ON INSIDE
12-02-2002

Advertisement

loading

Summary of Contents for Schlage CM5100-KPI

  • Page 1 PRO5100 CM5198 Track 3 card reader (data on track 3 must be ABA track 2 format) - MGI/MGK only SAFE SCHOOL LOCK WITH iBUTTON Keyed Different, includes Schlage READER ON INSIDE Everest cylinder Less Cylinder Form 51005 Rev. D 12-02-2002...
  • Page 2: Before You Begin

    CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL BEFORE YOU BEGIN: Standard units are shipped from the factory to fit 1-3/4” doors. Verify that the door thickness. If the door is not 1-3/4” thick, verify that the door thickness option was ordered or consult factory. 1.
  • Page 3 G. Install standoffs. TEST KEY OPERATION NOW: Turning key clockwise until it stops (about 1/2 turn) should allow the lever to turn retractor. RECOMMENDED CAMS: NOTE SCHLAGE EVEREST: P/N B502-948 BLOCKING RING REQUIRED FOR CYLINDER SCHLAGE CLASSIC: P/N B502-191 1-1/8”.
  • Page 4 CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL 3. CHANGE HAND (IF NECESSARY): NOTE: The locks are shipped handed as ordered from factory. If it is necessary to change the hand of the lock, follow the steps below: A. Remove retractor by loosening two 9/64” socket cap screws which attach it to the outside escutcheon. B.
  • Page 5 CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL 4. INSTALL STRIKE BOX AND STRIKE: 5. INSTALL LATCH AND OUTSIDE ESCUTCHEON: A. Install latch into edge of door. Be sure to install it with the beveled edge facing door jamb. B. If the door is less than 1-3/4 thick, slide spacer over standoffs and retractor on outside escutcheon. C.
  • Page 6 CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL 6. INSTALL BASE PLATE ASSEMBLY: Install base plate assembly onto inside of door. (If the door is less than 1-3/4” thick, install spacer between the base plate and the door.) Use socket cap screws with washers on upper standoffs and phillips head screws on lower (retractor assem- bly) standoffs.
  • Page 7 CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL 7. INSTALL INSIDE SPINDLE, BATTERIES, AND INSIDE ESCUTCHEON: NOTE: The lock is shipped with four AA alkaline batteries. Always use new, high quality alkaline batteries. A. Plug wiring harness into PC board. B. Tuck wiring harness under retaining clip as shown in detail. C.
  • Page 8: Operational Test

    CM5100 COMPUTER MANAGED CYLINDRICAL LOCK INSTALLATION MANUAL OPERATIONAL TEST: TROUBLE SHOOTING: 1. Push down and up on inside lever: latch should PROBLEM: POSSIBLE CAUSE: retract. Inside lever doesn’t Inside spindle not installed retract latch: 2. Push down and up on outside lever. Lever should be disengaged from retractor and door should not No response from key- Wiring harness not plugged...