Prospray 3.25 Connection Diagram - WAGNER ProSpray 3.25 Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for ProSpray 3.25:
Table of Contents

Advertisement

Repairs at the unit
17. Carefully tighten retainer nut (5) with adjusting wrench
18. Slide the top of the piston (3) into the T-slot (9) on the
slider assembly (4).
19. Position the pump manifold (2) underneath the gear unit
housing and push up until it rests against the gear unit
housing.
20. Attach pump manifold (2) to the gear unit housing.
21. Screw pump manifold (2) tightly to gear unit housing.
22. Lubricate O-ring (Fig. 13, Item 6) between pump manifold
(2) and inlet valve housing with machine grease. Screw
inlet valve housing to the pump manifold.
11.4

ProSpray 3.25 connection diagram

White
Switch
Surge suppressor
Uncontrolled Copy
GB
EMI Filter
Fuse block
Ground
Fuse
Black
Black
White
White
Red
Black
Motor
18
23.
unit on high-rider cart:
Thread the siphon tube into the inlet valve and tighten
securely. Make sure to wrap the threads on the down
tube with PTFE tape before assembly. Replace the return
hose into the hose clip on the siphon tube.
unit on stand / low boy cart:
Insert the elbow on the siphon assembly into the bottom
of the pusher stem housing. Push the retaining clip up
into the groove inside the foot valve housing to secure the
siphon assembly in position. Place the return tube over
the return tube fitting and secure with the clip.
24. Install front cover.
Power Cord
Black
Red
Red (+)
Black (-)
Capacitor
Motor controller
L.E.D.
Hall sensor
Potentiometer
Display wire
assembly
Pressure sensor
ProSpray 3.25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents