9.12 CoNSole reMoVal
1) Turn off the power and disconnect the cord from the machine.
2) Remove the 4 screws holding the console back to the front (Figure A).
3) Lean the console back away from the console and disconnect the coax cable connection.
4) Remove the six 6 mm screws from underneath the console. There are arrows stamped in the plastic at the proper openings (Figure C).
fiGUre a
5) Disconnect the remaining connectors holding the console to the frame and remove the console.
6) Reverse Steps 1-5 to install a new console.
This port is not used
with the Delta MCB (is
used with the DCI MCB)
8 pin black connector
from the console cable
2 pin black connector from
the Emergency Stop
8 pin white connector
from the console cable
7) Auto Calibration must ALWAYS be run after replacing the console (see Section 3.5).
CHaPTer 9: ParT rePlaCeMeNT GUiDe
NOTE: Be sure to re-connect any wire connections removed in Steps 3 and 4 (Figure D).
fiGUre B
fiGUre C
20 pin gray connector
from the HR Board
65