GB
Code
Problem
15
Bus charging fault
19
Torch trigger early
engagement
20
No return at PIP (Parts In
Place) check of consum
ables.
21
No unbroken current path at
PIP (Parts In Place) check of
consumables.
8
ORDERING SPARE PARTS
Repair and electrical work should be performed by an authorized ESAB serviceman.
Use only ESAB original spare and wear parts.
Powercut 900 is designed and tested in accordance with the international and Europe
an standards 60974-1 and 60974-10. It is the obligation of the service unit which has
carried out the service or repair work to make sure that the product still conforms to
the said standard.
Always provide the serial number of the unit on which the parts will be used. The
serialnumber is stamped on the units rating plate.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
bp17ea
Cause
Under voltage on the primary
bus.
Torch trigger depressed at
power up.
The piston was not
withdrawn when air was
released.
The piston did not fall back
when the air supply was
removed.
- 19 -
Solution
Check the bus charger.
Check the trigger.
Check/clean consumables.
Check the compressed air
supply.
Check/clean consumables.