Configuring Alerts - Seneca XVAULT xNVR200 Hardware User's Manual

Table of Contents

Advertisement

CHeCK CONsisTeNCY raTe
Check Consistency is a RaID controller data integrity check function. It is not advisable to completely stop consistency checks or to
reduce to below 10%.
Vii. CONFiGUriNG aLerTs
the xNVR series has the ability to send out RaID array status alerts via email. the ability to transmit alerts requires an in-management
subnet SMtP server or to be routed to the SMtP server. Please consult with the network administrator for SMtP network information
and access.
the alerts subsystem supports four levels of alert. Fatal which is the catastrophic failure of a component within the RaID subsystem.
Critical alerts are flagged when the subsystem cannot sustain another failure without high probably of going down. warnings are
issued when non-critical errors are detected/recorded. informational alerts are issued when there are changes in configuration, login
or orderly processes occurring such as system shutdown or startup.
Each of the alert levels are notification configurable. there are four methods that an alert can be delivered; Supported operating
system Log, system monitor Pop Up, MsM Log and/or email.
aLerT TriGGers
aLerT
Chassis Fan Failure
Power Supply Failure (redundant configurations only)
thermal
Drive Failure and Unordinary Status
RaID Set Integrity Issues
any array or array Controller Status Change
In addition to basic alert level conveyance via four vehicles, specific Individual Events can have the delivery method changed.
External expansion chassis with 2U 12 Bay, 3U 16 Bay or 4U 24 Bay configuration will also report same xNVR alert triggers via email.
xVault xNVR200/300/400 User Guide V2.0.0
2U 4 Bay
2U 8 Bay
X
X
X
X
2U 12 Bay
3U 16 Bay
X
X
X
X
X
X
X
X
X
X
configurable
configurable
4U 24 Bay
X
X
X
X
X
configurable