Functions - Sony PDW-F800 Operation Manual

Professional disc camcorder
Hide thumbs Also See for PDW-F800:
Table of Contents

Advertisement

ASSIGN 5 switch (PDW-F800), or RET button
on the lens)) (when the RM REC START item
on the CAM CONFIG 2 page of the
MAINTENANCE menu is set to RM)
[700]
• Buttons to which the COLOR TEMP SW
3200K/4300K/5600K/ 6300K functions have
been assigned (ASSIGN 1/3/4 switches,
COLOR TEMP. button, and RET button on the
lens)
Paint adjustment when the remote
control unit is connected
The settings of the paint adjustment that were in
effect the last time the remote control unit was
used are recalled.
Function of the recording start/stop
buttons when the remote control unit is
connected
When the remote control unit is connected, you
can make a setting to determine which of the
recording start/stop buttons you will use. This
setting is made using the RM REC START item
on the CAM CONFIG 2 page of the
MAINTENANCE menu.
Relationship between the setting of the RM REC
START item and the function of recording start/
stop buttons
Recording start/
Settings of RM REC
stop button
START
RM
Camcorder's REC
Disabled Enabled Enabled
START button
Lens VTR button
Disabled Enabled Enabled
Button to which the
Disabled Enabled Enabled
recording start/stop
function has been
assigned
(camcorder
ASSIGN 1/3/4
switch, COLOR
TEMP. button
(PDW-700),
ASSIGN 5 switch
(PDW-F800), or
RET button on the
lens)
When the monitor is connected to the
MONITOR OUT connector of the remote
control unit
The MONITOR connector (BNC type) of the
RM-B150/B750 outputs the same signal as that
from the TEST OUT connector on the camcorder.
Use the black cable supplied with the RM-B150/
B750 to connect the monitor to the MONITOR
connector on the RM-B150/B750.
When the remote control unit is
disconnected from the camcorder
The camcorder settings return to the settings in
effect before the remote control unit was
connected.
Structure of the paint adjustment data
The non-volatile memory of the camcorder used
for storing paint adjustment data consists of two
regions as shown below: one is the "independent
data region" that is used when a remote control
unit is not connected, and the other is the "remote
control data region" that is used when a remote
control unit is connected. Paint adjustment data is
automatically selected and output to the camera
section depending on whether or not a remote
control unit such as the RM-B150 is connected.
CAM
PARA
Recording start/
Settings of RM REC
stop button
START
RM
Remote control
Enabled Disabled Enabled
unit's VTR button
Connecting the Remote Control Unit
CAM
PARA
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdw-700

Table of Contents