Growatt ShineVision Operation Manual

Growatt ShineVision Operation Manual

Advertisement

GROWATT NEW ENERGY CO., LTD
No.12 Building, Xicheng Industrial
Zone, Bao'an District, Shenzhen, P. R.China
T
+ 86 755 2747 1900
F
+ 86 755 2749 1460
E
service@ginverter.com
W
www.ginverter.com
GR - UM - 007 - 01
ShineVision
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ShineVision and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt ShineVision

  • Page 1 ShineVision Operation Manual GROWATT NEW ENERGY CO., LTD No.12 Building, Xicheng Industrial Zone, Bao’an District, Shenzhen, P. R.China + 86 755 2747 1900 + 86 755 2749 1460 service@ginverter.com www.ginverter.com GR - UM - 007 - 01...
  • Page 2: Table Of Contents

    Table of Contents Product Overview Basic Operations and Display of Functions 2.1 Check of software version and clear 2.2 Code-matching operation 2.3 Basic Setting 2.3.1 Currency symbol setting 2.3.2 Income coefficient setting 2.3.3 CO2 coefficient setting 2.3.4 Date setting 2.3.5 Time setting 2.3.6 Temperature unit setting 2.3.7 Buzzer setting 2.4 Data storage...
  • Page 3: Product Overview

    Basic Operations and Display of Functions 2.1 Check of software version and clear ShineVision, which consists of a power monitor and a number of transmitters, can achieve 1 to 6 monitoring modes. The transmitters transmit the power data collected from a photovoltaic inverter to the monitor and display the data onto the monitor Insert power supply (or batteries) after pressing “up”...
  • Page 4: Basic Setting

    After the power is energized, the default interface displays, press “down” and “up” keys shortly and select the channel No. (optional from channel No.1 to 6), and press the “down” key for about 3 seconds until the red LED light quickly flash twice , then release it.
  • Page 5: Co2 Coefficient Setting

    after adjustment, then the “6” of 0.163 will flash; press “Up” or “Down” to adjust from 0 to 9, and press “OK” to confirm after adjustment, then the fourth figure “1” its value, ranging from 0 to 9, and press “OK” to confirm after adjustment, then the of the Year “2011”...
  • Page 6: Buzzer Setting

    2.3.6 Temperature unit setting not be reset until the beginning of the next month or execution of reset. The total generated energy, total generation revenue and total CO2 emissions are always stored and will not be reset until data resetting is performed. When “Temp.”...
  • Page 7: Default Interface Display

    2.6 Default interface display There are two modes in the third line, one showing the generated energy, generation revenue and CO2 emissions in the month and the other showing the total generated energy, total generation revenue and total CO2 emissions. Two modes are divided into six interfaces and each interface is displayed after every 5s in cycle, as shown in LCD will automatically refresh its display in the default interface.
  • Page 8: Reading Of Data Of Emitter No.1 To 6

    The second line shows phase voltage for three-phase AC of each channel. The third line shows two-circuit PV voltage for each channel. If you have some requirements or problems concerning ShineVision, please The fourth line shows time and real-time temperature under the current contact us and provide related information.